FSSAI Food Analyst and Junior Analyst Examinations · India · Food Safety and Standards Authority of India
Original practice questions written to the published syllabus · not past papersFSSAI Food Analyst and Junior Analyst Examinations is a licensing and registration exam run by Food Safety and Standards Authority of India, for candidates in India.
Official site: fssai.gov.in.
We have not been able to confirm these details against the exam body's own specification, so fees, dates and pass marks are left out on purpose. Check the current format, eligibility, fees and dates on the official site.
Quality systems, statistical process control, sampling inspection and running an accredited dairy laboratory.
Our 30 FSSAI Food Analyst and Junior Analyst Examinations questions in this subject: 6 easy, 17 medium, 7 hard, across 3 units.
Choose an answer, then open the working. Each explanation says why the right answer is right and why the others are not.
These 10 were written to FSSAI Food Analyst and Junior Analyst Examinations and are not shown on any other exam's page.
How many standard sections does a GHS safety data sheet contain?
A. 16
The GHS safety data sheet has sixteen sections, from identification and hazard identification through handling, exposure controls and disposal to regulatory and other information.
When preparing a dilute acid in the laboratory, the safe practice is to:
A. Add the acid slowly to the water with stirring
Adding acid to water lets the large volume of water absorb the heat of dilution. Adding water to concentrated sulphuric acid can boil locally and spatter acid.
Why do many milk-recording and payment laboratories avoid potassium dichromate as a preservative for composite samples?
B. It is toxic and carcinogenic, so safer preservatives are preferred
Hexavalent chromium compounds such as potassium dichromate are toxic and carcinogenic, and their disposal is problematic, so many laboratories use less hazardous preservatives where the method allows. It is not universally banned; it suppresses rather than promotes bacterial growth.
A plant laboratory is asked to culture and confirm Brucella from raw milk samples. What is the most appropriate response?
C. Send the work to a laboratory with the higher containment it requires
Brucella is a well-known cause of laboratory-acquired infection, and work with its cultures needs higher biosafety containment than routine indicator counts. Fume cupboards protect against chemical vapours, not aerosols of pathogens; preservatives do not make culture safe.
Under ISO/IEC 17025:2017, what is 'option B' for the management system?
D. Operating an ISO 9001 system that also supports the laboratory requirements
Clause 8 lets a laboratory meet the management-system requirements either directly (option A) or through a system run to ISO 9001 that supports the technical requirements (option B). Internal audit is required either way, and ISO does not audit laboratories.
In measurement uncertainty, what is a Type B evaluation?
C. Evaluation by means other than statistics of repeated measurements
Type A components are evaluated statistically from repeated observations; Type B components come from other information such as calibration certificates, tolerances and published data. The labels say nothing about the type of test.
Using the convention LOD = 3 × s(blank) and LOQ = 10 × s(blank), what are the LOD and LOQ when the standard deviation of blank results is 0.4 µg/kg?
B. LOD 1.2, LOQ 4.0 µg/kg
LOD = 3 × 0.4 = 1.2 µg/kg; LOQ = 10 × 0.4 = 4.0 µg/kg. Other conventions exist, which is why the stem states this one. Swapping them or using 1× and 3× gives the wrong pairs.
Organisations that run proficiency-testing schemes are accredited against which standard?
A. ISO/IEC 17043
PT providers are accredited to ISO/IEC 17043. ISO/IEC 17025 is for testing and calibration laboratories, ISO 9001 for quality management systems and ISO 19011 gives guidance on auditing.
What is the difference between a correction and a corrective action?
B. A correction fixes the instance; corrective action removes the cause
Correction deals with the immediate nonconformity (for example repeating a test); corrective action finds and eliminates the root cause so it does not recur, and its effectiveness is checked.
Where no proficiency scheme exists for a test, how can a laboratory provide external evidence of its validity?
C. Interlaboratory comparison or analysis of certified reference materials
Interlaboratory comparisons with a competent laboratory, and analysis of certified reference materials (produced under ISO 17034), give external evidence when no PT scheme is available. Repeating one's own tests only shows repeatability.
This plan follows where our questions actually fall, so the time goes where the marks are likely to be. It is our reading of the syllabus, not the exam body's weighting.
Read the manual chapters for these first and do every worked question you can find on them.
Aim for one sitting per unit, then mixed questions across them.
Learn the definitions, classifications and standard numbers; these units are more often recalled than worked.
Come back to these after a first pass, untimed, and read every explanation, including for the options you rejected.
Do these early in revision so they are fast on the day.
Last updated · How Laisha writes and checks its pages · Report a mistake
US$10 a month · one price worldwide · cancel any time
| Free | Smarter | |
|---|---|---|
| Grow guides, pest pages, articles | Read all | Read all |
| Ask Laisha | 5 a day | Up to 1,000 a month |
| Exam practice | The sample on each page | Every question, timed papers |
| Crop calendar and pest alerts | — | For your own fields |
| Calculators and tools | — | All |
| Uploads and reports | — | 100 a month, real files |
An AI operating system for agriculture: free guides, manuals and tools written for every country.