ICAR AIEEA (PG): Master's entrance, Veterinary Science and Animal Sciences · India · NTA for ICAR
Original practice questions written to the published syllabus · not past papersICAR AIEEA (PG): Master's entrance, Veterinary Science and Animal Sciences is a postgraduate admission exam run by NTA for ICAR, for candidates in India. Computer-based, 120 MCQs in 120 minutes, +4 for correct and -1 for wrong, maximum 480. English only.
Source: icar.org.in.
Checked against the exam body's published information. Formats and fees change; confirm the current edition there before you book.
One-line recall: X-ray tube parts and target material, kVp versus mAs, heel effect, inverse square law, grids, film processing chemicals, radiographic opacities, dose units and limits, contrast media and their contraindications, ultrasound frequencies and artefacts, and pregnancy diagnosis timings in cattle and mares.
X-ray physics and radiation safety, positioning and interpretation, contrast studies, ultrasonography (including reproductive), endoscopy and the basics of CT and MRI.
Our 34 ICAR AIEEA questions in this subject: 18 easy, 14 medium, 2 hard, across 9 units.
Choose an answer, then open the working. Each explanation says why the right answer is right and why the others are not.
These 10 were written to ICAR AIEEA and are not shown on any other exam's page.
Which exposure factor mainly controls the penetrating power (quality) of the X-ray beam and therefore radiographic contrast?
D. The kilovoltage peak (kVp) applied across the tube
kVp sets photon energy, so it controls penetration and contrast. mAs controls the number of photons (quantity, density); time is one component of mAs; focal spot size affects sharpness, not beam quality.
The line focus principle in X-ray tube design achieves which of the following?
A. A small effective focal spot while a larger actual area of target absorbs the heat
Angling the target makes the area struck by electrons long and narrow (good for heat) but, viewed from the patient, the effective spot is small (good for sharpness). The angled target actually causes the heel effect rather than removing it, and it does not change the characteristic/bremsstrahlung ratio.
A radiograph is made at 200 mA with an exposure time of 0.05 s. What is the mAs?
C. 10 mAs
mAs = mA × time in seconds = 200 × 0.05 = 10 mAs. 40 comes from dividing 200 by 5; 4 from 200 × 0.02; 100 from forgetting the decimal (200 × 0.5).
Using the 15% rule, a thorax exposure of 70 kVp and 20 mAs is changed to about 80 kVp to shorten the exposure. What mAs gives approximately the same film density?
B. 10 mAs
70 × 1.15 ≈ 80.5 kVp, so a 15% increase in kVp is roughly equivalent to doubling mAs. To keep density the same, halve mAs: 20 / 2 = 10 mAs. 40 mAs doubles instead of halving and would over-expose badly; 17 mAs cuts mAs by only 15% (20 / 1.15).
A focused grid has lead strips 2.4 mm high separated by radiolucent spaces 0.3 mm wide. What is its grid ratio?
C. 8:1
Grid ratio = height of strips / width of the interspace = 2.4 / 0.3 = 8, so 8:1. 0.125 inverts the fraction; 2.7 adds the two dimensions. Higher ratios clean up more scatter but need more exposure.
What is the SI unit of absorbed radiation dose?
A. The gray (Gy), equal to one joule per kilogram
Absorbed dose is measured in grays (1 Gy = 1 J/kg). The sievert is for equivalent and effective dose; the becquerel measures radioactivity; the roentgen is an old unit of exposure (ionisation in air), not absorbed dose.
The three basic physical methods of reducing occupational radiation exposure are:
B. Time, distance and shielding
Minimise time (and repeat exposures), maximise distance (inverse square law) and use shielding. Collimation and filtration also help, but the classic triad is time, distance and shielding.
Radiation-induced cancer is an example of which type of effect?
C. A stochastic effect: probability rises with dose and no safe threshold is assumed
Cancer and heritable effects are stochastic: the chance of the effect rises with dose, not its severity, and no threshold is assumed. Deterministic effects such as erythema and cataract have thresholds and their severity increases with dose.
Border effacement (the silhouette sign) occurs when:
B. Two structures of the same opacity are in contact
A border is only visible where opacities differ. When two soft-tissue or fluid structures touch, their shared border disappears, as when pleural fluid effaces the heart.
A double-contrast cystogram uses:
C. A small volume of positive contrast plus gas distension of the bladder
Double contrast combines a small amount of positive medium to coat the mucosa and gas to distend the lumen, showing mucosal lesions, filling defects and calculi well.
This plan follows where our questions actually fall, so the time goes where the marks are likely to be. It is our reading of the syllabus, not the exam body's weighting.
Read the manual chapters for these first and do every worked question you can find on them.
Aim for one sitting per unit, then mixed questions across them.
Learn the definitions, classifications and standard numbers; these units are more often recalled than worked.
Come back to these after a first pass, untimed, and read every explanation, including for the options you rejected.
Do these early in revision so they are fast on the day.
Last updated · How Laisha writes and checks its pages · Report a mistake
US$10 a month · one price worldwide · cancel any time
| Free | Smarter | |
|---|---|---|
| Grow guides, pest pages, articles | Read all | Read all |
| Ask Laisha | 5 a day | Up to 1,000 a month |
| Exam practice | The sample on each page | Every question, timed papers |
| Crop calendar and pest alerts | — | For your own fields |
| Calculators and tools | — | All |
| Uploads and reports | — | 100 a month, real files |
An AI operating system for agriculture: free guides, manuals and tools written for every country.