LAISHA
Open Laisha

GATE AG Instrumentation, Process Control & Automation: practice questions

GATE — Agricultural Engineering (AG), for dairy engineering aspirants · India · IITs and IISc on rotation

Original practice questions written to the published syllabus · not past papers
10worked here, free
22written to this exam in this subject
7syllabus units

About GATE AG

GATE — Agricultural Engineering (AG), for dairy engineering aspirants is a postgraduate admission exam run by IITs and IISc on rotation, for candidates in India.

Official site: gate2026.iitg.ac.in.

We have not been able to confirm these details against the exam body's own specification, so fees, dates and pass marks are left out on purpose. Check the current format, eligibility, fees and dates on the official site.

Instrumentation, Process Control & Automation in GATE AG

Measuring and controlling temperature, flow, pressure and level in a milk plant, from sensors to PLC and SCADA.

Our 22 GATE AG questions in this subject: 0 easy, 18 medium, 4 hard, across 7 units.

10 practice questions, worked

Choose an answer, then open the working. Each explanation says why the right answer is right and why the others are not.

These 10 were written to GATE AG and are not shown on any other exam's page.

Question 1 · medium

A first-order temperature probe has a time constant of 5 s. About how long after a step change does it reach 95% of the final change?

  1. About 10 s
  2. About 25 s
  3. About 5 s
  4. About 15 s
Answer and working

D. About 15 s

1 − e^(−t/τ) = 0.95 gives t ≈ 3τ = 15 s. 5 s is one time constant (63.2%), 10 s is two (86.5%) and 25 s is five (about 99.3%).

Question 2 · medium

A thermocouple with an assumed constant Seebeck coefficient of 41 µV/°C has its hot junction at 120 °C and its reference junction at 25 °C. What emf does it produce?

  1. About 5.95 mV
  2. About 4.92 mV
  3. About 3.90 mV
  4. About 1.03 mV
Answer and working

C. About 3.90 mV

emf = 41 µV/°C × (120 − 25) = 3,895 µV ≈ 3.90 mV. 4.92 mV ignores the reference junction; 1.03 mV uses only the reference temperature; 5.95 mV adds the two temperatures.

Question 3 · hard

A Pt100 (α = 0.00385 per °C) is wired with two copper leads of 0.5 Ω each in a two-wire circuit. Roughly what error do the leads cause?

  1. About 2.6 °C too low
  2. About 2.6 °C too high
  3. About 0.4 °C too high
  4. About 1.3 °C too high
Answer and working

B. About 2.6 °C too high

Two leads add 1.0 Ω in series; 1.0 ÷ 0.385 Ω/°C ≈ 2.6 °C, and extra resistance reads as higher temperature. 1.3 °C counts one lead only; the error is not low; 0.4 °C uses 0.385 as the answer.

Question 4 · medium

An orifice meter shows 40 kPa differential at 20,000 L/h. If the flow falls to 10,000 L/h, what differential will it show?

  1. 28 kPa
  2. 10 kPa
  3. 20 kPa
  4. 5 kPa
Answer and working

B. 10 kPa

Flow ∝ √ΔP, so ΔP ∝ flow²: halving flow gives (½)² × 40 = 10 kPa. 20 kPa assumes a linear relation; 5 kPa cubes; 28 kPa takes 40 × 1/√2.

Question 5 · medium

The differential across a venturi falls to one quarter of its earlier value. The flow is now:

  1. One sixteenth of its earlier value
  2. One quarter of its earlier value
  3. Half its earlier value
  4. Twice its earlier value
Answer and working

C. Half its earlier value

Flow ∝ √ΔP, so √(1/4) = 1/2. A quarter assumes linearity; a sixteenth squares instead of rooting; flow cannot rise when differential falls.

Question 6 · hard

A hydrostatic level transmitter in a silo was set up for water (1,000 kg/m³). The silo now holds milk of 1,032 kg/m³. If the true milk depth is 5.0 m, what depth does the transmitter show?

  1. About 5.32 m
  2. About 5.16 m
  3. About 5.00 m
  4. About 4.84 m
Answer and working

B. About 5.16 m

Pressure = 1,032 × 9.81 × 5.0; read as water depth: 5.0 × 1,032/1,000 = 5.16 m. 4.84 m divides the wrong way; 5.00 m ignores the density change; 5.32 m doubles the error.

Question 7 · medium

A valve with Kv = 8 passes water at a 1.44 bar pressure drop. Using Q = Kv √ΔP, what is the flow?

  1. 11.5 m³/h
  2. 8.0 m³/h
  3. 9.6 m³/h
  4. 6.7 m³/h
Answer and working

C. 9.6 m³/h

Q = 8 × √1.44 = 8 × 1.2 = 9.6 m³/h. 11.5 omits the square root; 6.7 divides by √ΔP; 8.0 ignores the pressure drop.

Question 8 · medium

A centrifugal CIP pump's speed is reduced by 20% with a variable-frequency drive. By the affinity laws, roughly what saving in shaft power results?

  1. About 49%
  2. About 64%
  3. About 36%
  4. About 20%
Answer and working

A. About 49%

Power ∝ speed³: 0.8³ = 0.512, a saving of about 49%. 20% assumes power ∝ speed; 36% uses the square law for head; 64% is the head ratio, not a saving.

Question 9 · medium

A 4–20 mA level transmitter is ranged 0–5 m. What current corresponds to 3.5 m?

  1. 15.2 mA
  2. 11.2 mA
  3. 14.0 mA
  4. 17.5 mA
Answer and working

A. 15.2 mA

I = 4 + 16 × (3.5 ÷ 5) = 15.2 mA. 14.0 mA uses 20 × 0.7; 11.2 mA omits the 4 mA offset; 17.5 mA uses 25 × 0.7.

Question 10 · medium

An HTST pasteuriser gives an average holding time of 16 s at 9,000 L/h. If flow rose to 10,000 L/h with the same holding tube, what would the average holding time be?

  1. 17.8 s
  2. 16.0 s
  3. 12.8 s
  4. 14.4 s
Answer and working

D. 14.4 s

Holding time ∝ 1/flow: 16 × 9,000 ÷ 10,000 = 14.4 s. 17.8 s scales the wrong way; 16.0 s ignores the change; 12.8 s subtracts 20%.

A study plan for Instrumentation, Process Control & Automation in GATE AG

This plan follows where our questions actually fall, so the time goes where the marks are likely to be. It is our reading of the syllabus, not the exam body's weighting.

  1. First, the heavy units (59% of the 22 questions): Temperature measurement: thermocouples, RTDs and recorders (5, 23%); Generalised measurement system and instrument characteristics (4, 18%); Pressure, flow and level measurement (4, 18%).

    Read the manual chapters for these first and do every worked question you can find on them.

  2. Then the middle band: Control modes: on-off, P, PI and PID (3, 14%); Final control elements: valves and drives (3, 14%); Programmable logic controllers (2, 9%).

    Aim for one sitting per unit, then mixed questions across them.

  3. Then the lighter units: Automation of pasteurisers, CIP and milk reception (1, 5%).

    Learn the definitions, classifications and standard numbers; these units are more often recalled than worked.

  4. Leave time for the hard ones: Temperature measurement: thermocouples, RTDs and recorders (2 hard of 5), Control modes: on-off, P, PI and PID (1 hard of 3), Pressure, flow and level measurement (1 hard of 4).

    Come back to these after a first pass, untimed, and read every explanation, including for the options you rejected.

  5. Finish timed. Sit the subject as a timed set without notes, mark it, and send each wrong answer back to its unit above.

Last updated · How Laisha writes and checks its pages · Report a mistake

Ask Laisha about this

Opens Laisha's chat with your question ready to send. Sign in or start free.

Unlock every question — GATE AG Instrumentation, Process Control & Automation

US$10 a month · one price worldwide · cancel any time

  • Every practice question in this subject, with full working
  • Timed exam papers and progress by unit
  • Ask Laisha to explain any answer — up to 1,000 questions a month
Free or Smarter
FreeSmarter
Grow guides, pest pages, articlesRead allRead all
Ask Laisha5 a dayUp to 1,000 a month
Exam practiceThe sample on each pageEvery question, timed papers
Crop calendar and pest alerts—For your own fields
Calculators and tools—All
Uploads and reports—100 a month, real files
10 days free for every new account, no card.