CUET-PG Environmental Monitoring & Instrumental Analysis: practice questions

CUET-PG — Environmental Sciences · India · National Testing Agency

Original practice questions written to the published syllabus · not past papers
10worked here, free
24written to this exam in this subject
12syllabus units

About CUET-PG

CUET-PG — Environmental Sciences is a postgraduate admission exam run by National Testing Agency, for candidates in India. Computer-based MCQ test for MSc admission to central and participating universities; pattern set in each year's bulletin.

Official site: exams.nta.ac.in.

We have not been able to confirm these details against the exam body's own specification, so fees, dates and pass marks are left out on purpose. Check the current format, eligibility, fees and dates on the official site.

Environmental Monitoring & Instrumental Analysis in CUET-PG

How environmental samples are taken and analysed and how good the numbers are: sampling plans, gravimetric and volumetric methods, spectroscopy, chromatography, quality assurance and monitoring networks.

Our 24 CUET-PG questions in this subject: 23 easy, 1 medium, 0 hard, across 12 units.

10 practice questions, worked

Choose an answer, then open the working. Each explanation says why the right answer is right and why the others are not.

These 10 were written to CUET-PG and are not shown on any other exam's page.

Question 1 · easy

How should water samples for dissolved metal analysis usually be preserved?

  1. Treated with sulphuric acid and heated to 100 °C
  2. Frozen with sodium thiosulphate
  3. Left at room temperature in glass bottles
  4. Filtration and nitric acid to pH below 2
Answer and working

D. Filtration and nitric acid to pH below 2

Nitric acid keeps metals in solution and prevents adsorption; thiosulphate is for chlorinated microbiological samples.

Question 2 · medium

Why are volatile organic compound water samples collected in vials with no headspace?

  1. To add oxygen that preserves the VOCs
  2. To allow microbes to degrade the VOCs quickly
  3. To make room for adding acid later
  4. To stop VOCs escaping into the vial air
Answer and working

D. To stop VOCs escaping into the vial air

Headspace would let volatile analytes partition out of the water.

Question 3 · easy

At what temperature is the residue dried for total dissolved solids?

  1. 180 °C
  2. 550 °C
  3. 103–105 °C
  4. 20 °C
Answer and working

A. 180 °C

TDS residue is dried at 180 °C; TSS at 103–105 °C; volatile solids are ignited at 550 °C.

Question 4 · easy

Which indicator is used in the EDTA titration for total hardness?

  1. Phenolphthalein
  2. Starch
  3. Eriochrome Black T
  4. Ferroin
Answer and working

C. Eriochrome Black T

Eriochrome Black T changes from wine-red to blue; phenolphthalein for alkalinity; starch for iodine; ferroin for COD.

Question 5 · easy

The Beer–Lambert law states that absorbance is proportional to

  1. concentration and path length
  2. the square of concentration
  3. temperature only
  4. wavelength only
Answer and working

A. concentration and path length

A = εbc: absorbance rises linearly with concentration and path length, not with temperature or wavelength alone.

Question 6 · easy

Which GC detector is extremely sensitive to halogenated compounds such as organochlorine pesticides?

  1. Electron capture detector
  2. Thermal conductivity detector
  3. Flame ionisation detector
  4. Refractive index detector
Answer and working

A. Electron capture detector

ECD responds strongly to electronegative halogens; FID is general for organics; TCD is universal but insensitive.

Question 7 · easy

Electrical conductivity of water increases mainly with

  1. the colour of the water
  2. the number of bacteria
  3. the amount of dissolved oxygen
  4. the concentration of dissolved ions
Answer and working

D. the concentration of dissolved ions

Ions carry current; conductivity indicates dissolved salts.

Question 8 · easy

A method gives results that cluster tightly but are consistently 20 per cent too high. It is

  1. neither precise nor accurate in any sense
  2. both accurate and precise
  3. accurate but not precise
  4. precise but not accurate
Answer and working

D. precise but not accurate

Tight clustering is precision; a consistent offset is bias, reducing accuracy.

Question 9 · easy

A stream sample contains 120 macroinvertebrates, of which 45 are mayflies, stoneflies and caddisflies. What is the EPT percentage?

  1. 45 per cent
  2. 2.7 per cent
  3. 37.5 per cent
  4. 62.5 per cent
Answer and working

C. 37.5 per cent

45/120 × 100 = 37.5%. 45 confuses count with percentage; 2.7 inverts; 62.5 is the non-EPT share.

Question 10 · easy

Which organisms are classic bioindicators of sulphur dioxide air pollution?

  1. Honeybees
  2. Lichens
  3. Coral polyps
  4. Earthworms
Answer and working

B. Lichens

Many lichens are sensitive to SO2; lichen diversity maps air quality.

A study plan for Environmental Monitoring & Instrumental Analysis in CUET-PG

This plan follows where our questions actually fall, so the time goes where the marks are likely to be. It is our reading of the syllabus, not the exam body's weighting.

  1. First, the heavy units (42% of the 24 questions): Bioindicators and biomonitoring (3, 13%); Sampling and preservation of water, soil, air and biota (3, 13%); Atomic absorption and ICP techniques (2, 8%); Detection limits, accuracy, precision and calibration (2, 8%).

    Read the manual chapters for these first and do every worked question you can find on them.

  2. Then the middle band: Electrochemical methods and sensors (2, 8%); Gas and liquid chromatography; mass spectrometry (2, 8%); Gravimetric and volumetric analysis (2, 8%); Monitoring objectives and network design (2, 8%).

    Aim for one sitting per unit, then mixed questions across them.

  3. Then the lighter units: Stable and radioactive isotopes in environmental analysis (2, 8%); UV-visible spectrophotometry and colorimetry (2, 8%); Continuous and low-cost sensor monitoring (1, 4%); Quality assurance, quality control and laboratory accreditation (1, 4%).

    Learn the definitions, classifications and standard numbers; these units are more often recalled than worked.

  4. Bank the easy marks: Bioindicators and biomonitoring (3 easy of 3); Atomic absorption and ICP techniques (2 easy of 2).

    Do these early in revision so they are fast on the day.

  5. Finish timed. Sit the subject as a timed set without notes, mark it, and send each wrong answer back to its unit above.

Last updated · How Laisha writes and checks its pages · Report a mistake

Ask Laisha about this

Opens Laisha's chat with your question ready to send. Sign in or start free.

Unlock every question — CUET-PG Environmental Monitoring & Instrumental Analysis

US$10 a month · one price worldwide · cancel any time

  • Every practice question in this subject, with full working
  • Timed exam papers and progress by unit
  • Ask Laisha to explain any answer — up to 1,000 questions a month
Free or Smarter
FreeSmarter
Grow guides, pest pages, articlesRead allRead all
Ask Laisha5 a dayUp to 1,000 a month
Exam practiceThe sample on each pageEvery question, timed papers
Crop calendar and pest alerts—For your own fields
Calculators and tools—All
Uploads and reports—100 a month, real files
10 days free for every new account, no card.