UGC NET Environmental Monitoring & Instrumental Analysis: practice questions
UGC NET — Environmental Sciences (subject code 89) · India · National Testing Agency for the University Grants Commission
Original practice questions written to the published syllabus · not past papers
10worked here, free
92written to this exam in this subject
12syllabus units
About UGC NET
UGC NET — Environmental Sciences (subject code 89) is a PhD, fellowship and lectureship exam run by National Testing Agency for the University Grants Commission, for candidates in India. Computer-based, 3 hours, two papers in one sitting: Paper 1 (teaching and research aptitude, 50 MCQs) and Paper 2 (subject, 100 MCQs), 2 marks each, no negative marking.
We have not been able to confirm these details against the exam body's own specification, so fees, dates and pass marks are left out on purpose. Check the current format, eligibility, fees and dates on the official site.
Environmental Monitoring & Instrumental Analysis in UGC NET
Principles and applications of titrimetry, gravimetry, colorimetry and UV–visible spectrophotometry, AAS, ICP, chromatography (GC, HPLC, IC), mass spectrometry, electrochemical methods, isotopes, sampling and preservation, and QA/QC concepts.
How environmental samples are taken and analysed and how good the numbers are: sampling plans, gravimetric and volumetric methods, spectroscopy, chromatography, quality assurance and monitoring networks.
Our 92 UGC NET questions in this subject: 21 easy, 47 medium, 24 hard, across 12 units.
10 practice questions, worked
Choose an answer, then open the working. Each explanation says why the right answer is right and why the others are not.
These 10 were written to UGC NET and are not shown on any other exam's page.
Question 1 · medium
What does the US EPA's data quality objectives process require before sampling begins?
Buying the most sensitive instrument available
Collecting as many samples as the budget allows
Defining the decision and tolerable errors
Choosing sites that are easiest to reach
Answer and working
C. Defining the decision and tolerable errors
DQOs derive sampling design from the decision and acceptable errors, not from convenience.
Question 2 · hard
What is the purpose of a chain-of-custody record?
Calibrating instruments before analysis
Documenting every sample transfer
Recording the weather during sampling only
Calculating the detection limit of a method
Answer and working
B. Documenting every sample transfer
Chain of custody proves sample integrity from collection to analysis.
Question 3 · medium
Mohr's method determines chloride by titration with
sulphuric acid using methyl orange
silver nitrate, chromate indicator
sodium thiosulphate using starch
EDTA using Eriochrome Black T
Answer and working
B. silver nitrate, chromate indicator
Red-brown silver chromate forms after all chloride precipitates as AgCl.
Question 4 · medium
Hexavalent chromium is commonly measured colorimetrically using
Ammonium molybdate
Nessler's reagent
1,5-diphenylcarbazide in acid
Eriochrome Black T
Answer and working
C. 1,5-diphenylcarbazide in acid
Diphenylcarbazide forms a red-violet complex with Cr(VI) at about 540 nm.
Question 5 · medium
Which technique gives the lowest detection limits for many trace metals and can measure isotope ratios?
Flame photometry
ICP-MS
Titration with EDTA
Flame AAS
Answer and working
B. ICP-MS
ICP-MS reaches ng/L levels and resolves isotopes; flame methods are less sensitive.
Question 6 · hard
Argon chloride (ArCl⁺) interferes with arsenic measurement in ICP-MS because
it reacts with arsenic to form a gas
it absorbs the arsenic emission line
it lowers plasma temperature below ionisation
it shares nominal mass 75 with arsenic
Answer and working
D. it shares nominal mass 75 with arsenic
40Ar35Cl⁺ has mass 75, like 75As⁺; collision/reaction cells remove it.
Question 7 · medium
Solid-phase extraction is used in sample preparation to
digest metals in strong acid
concentrate analytes
measure turbidity of water
dry soil samples at 105 °C
Answer and working
B. concentrate analytes
SPE cartridges trap analytes, achieving large concentration factors.
Question 8 · hard
Anodic stripping voltammetry measures trace metals by
weighing metal precipitates after drying
measuring light absorbed by metal atoms in a flame
plating them on an electrode, then stripping
separating metals in a gas chromatograph
Answer and working
C. plating them on an electrode, then stripping
Pre-concentration by electrodeposition gives very low detection limits.
Question 9 · hard
Biosensors based on acetylcholinesterase inhibition are used to screen for
organophosphate and carbamate pesticides
coliform bacteria
nitrate in groundwater
heavy metals such as lead
Answer and working
A. organophosphate and carbamate pesticides
These pesticides inhibit acetylcholinesterase, reducing enzyme activity; results need confirmation.
Question 10 · medium
Why do low-cost optical PM sensors often overestimate PM2.5 at high relative humidity?
Humidity destroys the sensor's laser
Humidity reduces actual particle numbers
Particles absorb water and swell
Water vapour is counted as ozone
Answer and working
C. Particles absorb water and swell
Hygroscopic growth increases apparent size and scattering; correction or drying is needed.
A study plan for Environmental Monitoring & Instrumental Analysis in UGC NET
This plan follows where our questions actually fall, so the time goes where the marks are likely to be. It is our reading of the syllabus, not the exam body's weighting.
First, the heavy units (38% of the 92 questions): Bioindicators and biomonitoring (9, 10%); Detection limits, accuracy, precision and calibration (9, 10%); Quality assurance, quality control and laboratory accreditation (9, 10%); Continuous and low-cost sensor monitoring (8, 9%).
Read the manual chapters for these first and do every worked question you can find on them.
Then the middle band: Gas and liquid chromatography; mass spectrometry (8, 9%); Monitoring objectives and network design (8, 9%); Stable and radioactive isotopes in environmental analysis (8, 9%); Atomic absorption and ICP techniques (7, 8%).
Aim for one sitting per unit, then mixed questions across them.
Then the lighter units: Electrochemical methods and sensors (7, 8%); Sampling and preservation of water, soil, air and biota (7, 8%); UV-visible spectrophotometry and colorimetry (7, 8%); Gravimetric and volumetric analysis (5, 5%).
Learn the definitions, classifications and standard numbers; these units are more often recalled than worked.
Leave time for the hard ones: Bioindicators and biomonitoring (3 hard of 9), Atomic absorption and ICP techniques (2 hard of 7), Electrochemical methods and sensors (2 hard of 7).
Come back to these after a first pass, untimed, and read every explanation, including for the options you rejected.
Bank the easy marks: Atomic absorption and ICP techniques (2 easy of 7); UV-visible spectrophotometry and colorimetry (2 easy of 7).
Do these early in revision so they are fast on the day.
Finish timed. Sit the subject as a timed set without notes, mark it, and send each wrong answer back to its unit above.