National Technical Qualification — Food Engineer (식품기사) and Food Industrial Engineer (식품산업기사) · South Korea · Human Resources Development Service of Korea (HRDK), Q-Net
Original practice questions written to the published syllabus · not past papersNational Technical Qualification — Food Engineer (식품기사) and Food Industrial Engineer (식품산업기사) is a licensing and registration exam run by Human Resources Development Service of Korea (HRDK), Q-Net, for candidates in South Korea. Written examination followed by a practical examination; graded national technical qualifications.
Official site: q-net.or.kr.
We have not been able to confirm these details against the exam body's own specification, so fees, dates and pass marks are left out on purpose. Check the current format, eligibility, fees and dates on the official site.
Mass and energy balances and the three transfer processes — momentum, heat and mass — applied to foods: pumping viscous products, heating cans and pouches, and moisture and gas movement through foods and packaging films.
Our 15 National Technical Qualification questions in this subject: 1 easy, 7 medium, 7 hard, across 10 units.
Choose an answer, then open the working. Each explanation says why the right answer is right and why the others are not.
These 10 were written to National Technical Qualification and are not shown on any other exam's page.
When scaling a mixing process from a 50 L pilot vessel to a 5,000 L production vessel, engineers commonly keep which quantity constant when the aim is similar turbulence intensity?
B. Power input per unit volume
Constant P/V is a common scale-up rule for turbulent mixing; constant rpm would give far higher power per volume in the large tank, and constant total power far lower.
100 kg of carrots at 88 % moisture (wet basis) are dried to 8 % moisture (wet basis). The water removed is closest to
A. 87.0 kg
Solids = 12 kg; dried product = 12/0.92 = 13.04 kg; water removed = 87.0 kg. 80.0 kg subtracts percentages; 88.0 kg removes all water; 81.0 kg takes 92 % of 88 kg.
A juice plant blends 400 kg of juice at 11 °Brix with 600 kg at 15 °Brix. The blend's °Brix is
A. 13.4
(400 × 11 + 600 × 15)/1,000 = (4,400 + 9,000)/1,000 = 13.4. 13.0 is the unweighted average; 12.6 swaps the masses; 26.0 adds the two Brix values.
2,000 kg/h of milk (cp = 3.9 kJ/kg K) is heated from 10 °C to 72 °C by steam condensing at 120 °C (hfg = 2,202 kJ/kg), condensate leaving saturated. The steam needed is closest to
A. 220 kg/h
ṁs = 2,000 × 3.9 × 62/2,202 = 220 kg/h. 214 uses hfg at 100 °C; 255 heats from 0 °C; 56 omits cp.
In a milk pasteuriser, raw milk at 4 °C is heated to 65 °C in the regeneration section and then to 72 °C. With equal flows, the regeneration efficiency is closest to
A. 90 %
(65 − 4)/(72 − 4) = 61/68 = 90 %. 85 % divides by 72 instead of 68; 10 % is the remaining heating share; 100 % would need no final heating.
Water leaving a pipe into a tank at 1.5 m/s has an exit loss coefficient K = 1.0. The energy lost per kilogram is
A. 1.125 J/kg
Loss = K v²/2 = 1.0 × 2.25/2 = 1.125 J/kg. 2.25 omits the /2; 0.75 uses v/2; 1.5 uses v instead of v².
A cooling section of a juice line underperforms. The juice-side film coefficient is about 800 W/m² K and the water side about 5,000 W/m² K. The most effective way to raise the overall coefficient is to
A. increase juice-side turbulence
The smaller film coefficient controls U; improving the juice side helps most. Raising water temperature reduces the driving force.
Milk is heated from 10 °C to 60 °C by hot water cooling from 80 °C to 40 °C in counter-current flow. The LMTD is closest to
D. 24.7 K
ΔT1 = 80 − 60 = 20 K, ΔT2 = 40 − 10 = 30 K; LMTD = 10/ln 1.5 = 24.7 K. 25.0 K is the arithmetic mean; 24.5 K is the geometric mean √(20 × 30); 40.0 K uses inlet-to-inlet difference.
During a long run, a milk heater's outlet temperature falls although steam supply is unchanged. The most likely cause is
D. fouling deposits adding resistance and lowering U
Protein and mineral fouling builds up resistance; plants clean on a schedule or when temperature or pressure drop limits are reached.
Carcass weight loss during chilling can be reduced by
B. lowering air velocity and raising humidity once the surface is cool
Evaporation rate rises with km (air velocity) and the vapour-concentration difference; spray chilling and humid air reduce it.
This plan follows where our questions actually fall, so the time goes where the marks are likely to be. It is our reading of the syllabus, not the exam body's weighting.
Read the manual chapters for these first and do every worked question you can find on them.
Aim for one sitting per unit, then mixed questions across them.
Learn the definitions, classifications and standard numbers; these units are more often recalled than worked.
Come back to these after a first pass, untimed, and read every explanation, including for the options you rejected.
Do these early in revision so they are fast on the day.
Last updated · How Laisha writes and checks its pages · Report a mistake
US$10 a month · one price worldwide · cancel any time
| Free | Smarter | |
|---|---|---|
| Grow guides, pest pages, articles | Read all | Read all |
| Ask Laisha | 5 a day | Up to 1,000 a month |
| Exam practice | The sample on each page | Every question, timed papers |
| Crop calendar and pest alerts | — | For your own fields |
| Calculators and tools | — | All |
| Uploads and reports | — | 100 a month, real files |