LAISHA
Open Laisha

ICAR AIEEA-PG Dairy Analysis & Instrumental Methods: practice questions

ICAR AIEEA-PG: Dairy Science (group 16) and Dairy Technology (group 17) · India · NTA for ICAR

Original practice questions written to the published syllabus · not past papers
10worked here, free
85written to this exam in this subject
13syllabus units

About ICAR AIEEA-PG

ICAR AIEEA-PG: Dairy Science (group 16) and Dairy Technology (group 17) is a postgraduate admission exam run by NTA for ICAR, for candidates in India. Computer-based, 2 hours, 120 multiple-choice questions, +4 for a correct answer and −1 for a wrong one (2026 bulletin). One paper per major subject group.

Source: icar.org.in.

Checked against the exam body's published information. Formats and fees change; confirm the current edition there before you book.

Dairy Analysis & Instrumental Methods in ICAR AIEEA-PG

Tests for milk, butter, ghee and powder; detection of adulterants, neutralisers and preservatives; quality tests at reception.

Testing milk and dairy products: platform tests, reference methods, adulterant detection and modern instruments.

Our 85 ICAR AIEEA-PG questions in this subject: 28 easy, 45 medium, 12 hard, across 13 units.

10 practice questions, worked

Choose an answer, then open the working. Each explanation says why the right answer is right and why the others are not.

These 10 were written to ICAR AIEEA-PG and are not shown on any other exam's page.

Question 1 · medium

In the alcohol-alizarin test, a violet colour without flakes suggests that the milk is:

  1. Sour, with high developed acidity from bacterial growth
  2. Normal fresh milk of good quality
  3. Alkaline, possibly neutralised or mastitic
  4. Watered, with low solids
Answer and working

C. Alkaline, possibly neutralised or mastitic

Alizarin is violet in alkaline milk, lilac to red-brown in normal milk and yellow-brown in acid milk.

Question 2 · medium

A 4.000 gram milk sample leaves 0.508 gram of residue on drying. What is its total solids?

  1. 5.08 per cent
  2. 87.3 per cent
  3. 7.87 per cent
  4. 12.7 per cent
Answer and working

D. 12.7 per cent

0.508/4.000 x 100 = 12.7%; 87.3 is the moisture and 5.08 forgets to divide by the sample mass.

Question 3 · medium

What advantage does an FTIR milk analyser have over a filter instrument?

  1. It records the whole spectrum
  2. It needs no calibration
  3. It works without water reference
  4. It measures bacteria directly
Answer and working

A. It records the whole spectrum

Full spectra allow prediction of more components and flagging of abnormal samples.

Question 4 · easy

Which GC detector is especially sensitive to organochlorine pesticides?

  1. Electron-capture detector
  2. Refractive index detector
  3. Thermal conductivity detector only
  4. Flame ionisation detector
Answer and working

A. Electron-capture detector

ECD responds strongly to halogenated compounds.

Question 5 · medium

The European Union limit for aflatoxin M1 in milk is:

  1. 50 micrograms per kilogram
  2. 0.5 micrograms per kilogram
  3. 0.050 micrograms per kilogram
  4. 5 micrograms per kilogram
Answer and working

C. 0.050 micrograms per kilogram

EU 0.050 ug/kg; Codex, US and India 0.5 ug/kg.

Question 6 · medium

The reference method for aflatoxin M1 in milk uses:

  1. Immunoaffinity column clean-up and HPLC with fluorescence detection
  2. Kjeldahl digestion and titration
  3. Lactometer reading after skimming
  4. Gerber fat separation followed by weighing of the separated fat column
Answer and working

A. Immunoaffinity column clean-up and HPLC with fluorescence detection

ISO 14501/IDF 171 uses immunoaffinity columns and HPLC-fluorescence.

Question 7 · easy

Flame photometry is used mainly to determine:

  1. Fat and protein
  2. Lactose and sucrose
  3. Sodium and potassium
  4. Lead and cadmium
Answer and working

C. Sodium and potassium

Easily excited alkali metals emit at about 589 nm (Na) and 766 nm (K).

Question 8 · easy

The most common HPLC column type in food analysis is:

  1. Ion-exchange for sugars only
  2. Packed GC column
  3. Reversed-phase C18
  4. Size-exclusion only
Answer and working

C. Reversed-phase C18

Octadecylsilyl reversed-phase columns with water-organic mobile phases dominate.

Question 9 · medium

A laboratory reports 3.62 per cent fat against an assigned value of 3.50 per cent; the proficiency standard deviation is 0.05 per cent. What is the z-score?

  1. 0.12
  2. 2.4
  3. 0.24
  4. -2.4
Answer and working

B. 2.4

z = (3.62 - 3.50)/0.05 = 2.4 (questionable). 0.12 is the raw difference.

Question 10 · medium

What is a certified reference material?

  1. A sample sent by a customer for analysis
  2. A material with certified values, uncertainty and traceability
  3. Any sample analysed twice in the same laboratory on different days
  4. A reagent of analytical grade purity
Answer and working

B. A material with certified values, uncertainty and traceability

CRMs provide traceable values for checking accuracy.

A study plan for Dairy Analysis & Instrumental Methods in ICAR AIEEA-PG

This plan follows where our questions actually fall, so the time goes where the marks are likely to be. It is our reading of the syllabus, not the exam body's weighting.

  1. First, the heavy units (51% of the 85 questions): Protein: Kjeldahl and dye-binding; total solids and SNF (10, 12%); Fat determination: Gerber, Babcock and Rose-Gottlieb (9, 11%); Spectroscopy: UV-visible, infrared, atomic absorption and flame photometry (9, 11%); Method validation, reference materials and proficiency testing (8, 9%); Aflatoxin M1 detection (7, 8%).

    Read the manual chapters for these first and do every worked question you can find on them.

  2. Then the middle band: Antibiotic, pesticide and heavy-metal residue testing (7, 8%); Chromatography: TLC, GC and HPLC (7, 8%); Electrophoresis and immunoassays: SDS-PAGE, ELISA and lateral-flow tests (7, 8%); Infrared milk analysers and their calibration (7, 8%); Detection of adulterants: water, starch, urea, neutralisers, detergent, vegetable fat (4, 5%).

    Aim for one sitting per unit, then mixed questions across them.

  3. Then the lighter units: Ghee and butter fat adulteration: BR reading, Reichert-Meissl and Polenske values, sterol tests (4, 5%); Platform tests: organoleptic, COB, alcohol, sediment, lactometer (4, 5%); Sampling of milk and dairy products (2, 2%).

    Learn the definitions, classifications and standard numbers; these units are more often recalled than worked.

  4. Leave time for the hard ones: Detection of adulterants: water, starch, urea, neutralisers, detergent, vegetable fat (2 hard of 4), Aflatoxin M1 detection (2 hard of 7), Ghee and butter fat adulteration: BR reading, Reichert-Meissl and Polenske values, sterol tests (1 hard of 4).

    Come back to these after a first pass, untimed, and read every explanation, including for the options you rejected.

  5. Bank the easy marks: Platform tests: organoleptic, COB, alcohol, sediment, lactometer (3 easy of 4); Sampling of milk and dairy products (1 easy of 2).

    Do these early in revision so they are fast on the day.

  6. Finish timed. Sit the subject as a timed set without notes, mark it, and send each wrong answer back to its unit above.

Last updated · How Laisha writes and checks its pages · Report a mistake

Ask Laisha about this

Opens Laisha's chat with your question ready to send. Sign in or start free.

Unlock every question — ICAR AIEEA-PG Dairy Analysis & Instrumental Methods

US$10 a month · one price worldwide · cancel any time

  • Every practice question in this subject, with full working
  • Timed exam papers and progress by unit
  • Ask Laisha to explain any answer — up to 1,000 questions a month
Free or Smarter
FreeSmarter
Grow guides, pest pages, articlesRead allRead all
Ask Laisha5 a dayUp to 1,000 a month
Exam practiceThe sample on each pageEvery question, timed papers
Crop calendar and pest alerts—For your own fields
Calculators and tools—All
Uploads and reports—100 a month, real files
10 days free for every new account, no card.