ICAR AIEEA-PG Cleaning-in-Place, Sanitation & Hygienic Design: practice questions
ICAR AIEEA-PG: Dairy Science (group 16) and Dairy Technology (group 17) · India · NTA for ICAR
Original practice questions written to the published syllabus · not past papers
10worked here, free
23written to this exam in this subject
11syllabus units
About ICAR AIEEA-PG
ICAR AIEEA-PG: Dairy Science (group 16) and Dairy Technology (group 17) is a postgraduate admission exam run by NTA for ICAR, for candidates in India. Computer-based, 2 hours, 120 multiple-choice questions, +4 for a correct answer and −1 for a wrong one (2026 bulletin). One paper per major subject group.
Checked against the exam body's published information. Formats and fees change; confirm the current edition there before you book.
Cleaning-in-Place, Sanitation & Hygienic Design in ICAR AIEEA-PG
Dairy plant hygiene and sanitation, microbiology of equipment and personnel, CIP of dairy equipment, materials and sanitary features. Expect direct MCQs on detergents, sanitisers, CIP sequence and verification.
How dairy plants are cleaned and sanitised: fouling chemistry, detergents, sanitisers, CIP design and verification, and hygienic equipment design.
Our 23 ICAR AIEEA-PG questions in this subject: 18 easy, 5 medium, 0 hard, across 11 units.
10 practice questions, worked
Choose an answer, then open the working. Each explanation says why the right answer is right and why the others are not.
These 10 were written to ICAR AIEEA-PG and are not shown on any other exam's page.
Question 1 · medium
A 10 mL sample of CIP caustic needs 3.75 mL of 1 N HCl to neutralise it. What is its NaOH concentration (40 mg NaOH per meq)?
1.5% (w/v)
0.375% (w/v)
0.15% (w/v)
3.75% (w/v)
Answer and working
A. 1.5% (w/v)
3.75 meq × 40 mg = 150 mg in 10 mL = 1.5 g/100 mL. 0.375% ignores the 40 mg factor; 3.75% reads mL as %; 0.15% slips a decimal.
Question 2 · easy
A sanitiser reduces a surface count from 10⁶ to 10¹ cfu. How many log reductions is that?
1
5
6
10
Answer and working
B. 5
6 − 1 = 5 log units. 6 is the starting log; 1 is the final; 10 confuses the base.
Question 3 · easy
Type A fouling, typical of pasteuriser heating sections, is mainly:
Calcium phosphate scale
Milk fat
Protein
Lactose crystals
Answer and working
C. Protein
Type A deposits (about 75–110 °C) are soft, voluminous and protein-rich.
Question 4 · medium
Why does calcium phosphate deposit on hot surfaces?
Its solubility falls as temperature rises
It boils out of the milk with the water vapour
It is attracted electrically to stainless steel
It is produced from lactose by heating at the wall
Answer and working
A. Its solubility falls as temperature rises
Inverse solubility causes precipitation on the hottest surfaces.
Question 5 · easy
Milkstone on farm equipment forms when:
Equipment is rinsed too often
Acid cleaning is neglected
Alkaline cleaning is too strong
Milk is cooled too quickly
Answer and working
B. Acid cleaning is neglected
Calcium phosphate, protein and fat build up without periodic acid washes.
Question 6 · easy
Sinner's circle describes cleaning as a balance of:
pH, light, oxygen and water activity
Pressure, voltage, frequency and current
Fat, protein, lactose and minerals
Time, temperature, chemistry and mechanical action
Answer and working
D. Time, temperature, chemistry and mechanical action
Reducing one factor needs more of another.
Question 7 · medium
Which sanitiser leaves a residual film and is weak against Gram-negative bacteria and spores?
Hot water
Sodium hypochlorite
Peracetic acid
Quaternary ammonium compounds
Answer and working
D. Quaternary ammonium compounds
QACs are mainly used on environmental surfaces.
Question 8 · easy
Hot-water sanitising of closed equipment commonly uses water at about:
85–90 °C
40–45 °C
60 °C
20 °C
Answer and working
A. 85–90 °C
The coldest point of the circuit must reach the set temperature for the set time.
Question 9 · easy
Why are spray dryers often dry-cleaned between runs?
Wet powder deposits breed microbes
Water is not available in dryer halls
Dry cleaning removes calcium scale
Water makes the powder sterile
Answer and working
A. Wet powder deposits breed microbes
Wet cleaning is done at intervals and followed by thorough drying.
Question 10 · easy
A hygienic surface finish for product contact is commonly:
Ra ≥ 5 µm
Any finish
Ra ≤ 50 µm
Ra ≤ 0.8 µm
Answer and working
D. Ra ≤ 0.8 µm
Smoothness limits soil and bacterial attachment.
A study plan for Cleaning-in-Place, Sanitation & Hygienic Design in ICAR AIEEA-PG
This plan follows where our questions actually fall, so the time goes where the marks are likely to be. It is our reading of the syllabus, not the exam body's weighting.
First, the heavy units (57% of the 23 questions): Sanitisers: heat, chlorine, iodophors, quaternary ammonium, peracetic acid (5, 22%); Detergents: alkalis, acids, sequestrants and surfactants (3, 13%); Fouling and soil types in dairy plants (3, 13%); CIP systems: single-use, re-use and multi-tank (2, 9%).
Read the manual chapters for these first and do every worked question you can find on them.
Then the middle band: Hygienic design principles and 3-A and EHEDG guidance (2, 9%); Pest control and personal hygiene (2, 9%); Verification: ATP, swabs and visual inspection (2, 9%); Biofilm control (1, 4%).
Aim for one sitting per unit, then mixed questions across them.
Then the lighter units: CIP circuit design and flow velocity (1, 4%); Cleaning of membranes, evaporators and dryers (1, 4%); Mechanism of soil removal: time, temperature, chemistry, mechanical action (1, 4%).
Learn the definitions, classifications and standard numbers; these units are more often recalled than worked.
Bank the easy marks: Hygienic design principles and 3-A and EHEDG guidance (2 easy of 2); Pest control and personal hygiene (2 easy of 2).
Do these early in revision so they are fast on the day.
Finish timed. Sit the subject as a timed set without notes, mark it, and send each wrong answer back to its unit above.