ICAR AICE-JRF/SRF Cleaning-in-Place, Sanitation & Hygienic Design: practice questions
ICAR AICE-JRF/SRF (PhD): Dairy Chemistry, Dairy Microbiology, Dairy Technology, Dairy Engineering · India · NTA for ICAR
Original practice questions written to the published syllabus · not past papers
10worked here, free
67written to this exam in this subject
10syllabus units
About ICAR AICE-JRF/SRF
ICAR AICE-JRF/SRF (PhD): Dairy Chemistry, Dairy Microbiology, Dairy Technology, Dairy Engineering is a PhD, fellowship and lectureship exam run by NTA for ICAR, for candidates in India.
Checked against the exam body's published information. Formats and fees change; confirm the current edition there before you book.
Cleaning-in-Place, Sanitation & Hygienic Design in ICAR AICE-JRF/SRF
Unit 3: current trends in cleaning and sanitisation of dairy equipment, automation, ultrasonic techniques, biofilms, bio-detergents, innovations in sanitisers, mechanism of fouling and soil removal, assessing cleaning and sanitisation effectiveness, water conservation. Expect mechanism questions (type A and B fouling, Sinner's circle, biofilm resistance) and comparisons of sanitisers.
How dairy plants are cleaned and sanitised: fouling chemistry, detergents, sanitisers, CIP design and verification, and hygienic equipment design.
Our 67 ICAR AICE-JRF/SRF questions in this subject: 6 easy, 42 medium, 19 hard, across 10 units.
10 practice questions, worked
Choose an answer, then open the working. Each explanation says why the right answer is right and why the others are not.
These 10 were written to ICAR AICE-JRF/SRF and are not shown on any other exam's page.
Question 1 · medium
A CIP pump delivers 20 m³/h through a 50.8 mm internal diameter line. What is the flow velocity, and does it meet a 1.5 m/s target?
1.37 m/s, which just meets it
0.69 m/s, which falls short
9,868 m/s, far too fast
2.74 m/s, which meets it
Answer and working
D. 2.74 m/s, which meets it
v = (20 ÷ 3,600) ÷ (π × 0.0508² ÷ 4) = 2.74 m/s, above 1.5 m/s. The others forget the ÷4 in the area, the hour conversion, or halve the result.
Question 2 · hard
How much 1.75% available-iodine iodophor concentrate is needed for 500 L of sanitiser at 25 mg/L?
714,286 g
12.5 g
714 g
0.22 g
Answer and working
C. 714 g
Iodine = 500 × 25 mg = 12.5 g; concentrate = 12.5 ÷ 0.0175 = 714 g. 12.5 g is the iodine itself; the others multiply by the strength or forget mg-to-g conversion.
Question 3 · medium
Why is the pre-rinse done with cool or warm, not hot, water?
Cool water dissolves fat better than hot water
Hot water sterilises and wastes the detergent
Hot water bakes protein soil onto surfaces
Cold water removes calcium phosphate better
Answer and working
C. Hot water bakes protein soil onto surfaces
Heat can denature and fix protein residues.
Question 4 · medium
Sequestrants such as EDTA or gluconate are added to detergents to:
Neutralise the caustic before discharge
Sterilise the cleaned surfaces
Increase foaming for better visual cleaning
Prevent hardness scale
Answer and working
D. Prevent hardness scale
They bind hardness ions.
Question 5 · hard
For heavily mineral-rich (type B) deposits, a better sequence may be:
Acid first, then alkali, then acid
Hot water only
Sanitiser first, then a water rinse only
Alkali only at room temperature
Answer and working
A. Acid first, then alkali, then acid
Removing the mineral layer exposes protein to alkali.
Question 6 · hard
Why is evaporator run length limited even when heat transfer is still acceptable?
Detergent stocks run out after 6 hours
Milk quality improves with shorter runs only
The vacuum cannot be held for long
Thermophiles build up
Answer and working
D. Thermophiles build up
Spore counts in powder are a key specification.
Question 7 · easy
In infant formula powder plants, dry areas are monitored especially for:
Lactic acid bacteria
Clostridium tyrobutyricum spores
Salmonella and Cronobacter
Yeasts in brine
Answer and working
C. Salmonella and Cronobacter
These pathogens survive in dry environments.
Question 8 · medium
Membrane cleaning is verified mainly by:
Visual inspection of the housing
The temperature of the rinse
The colour of the permeate
Clean water flux recovery
Answer and working
D. Clean water flux recovery
Flux recovery shows whether fouling was removed.
Question 9 · medium
A limitation of ATP tests is that they:
Take several days to give any result
Do not identify specific micro-organisms
Cannot detect food residues
Need a culture incubator
Answer and working
B. Do not identify specific micro-organisms
Swabs and cultures identify organisms.
Question 10 · medium
EHEDG certifies equipment based on:
Cleanability testing
Energy rating
Sales volume
Colour of paint
Answer and working
A. Cleanability testing
Equipment is tested for in-place cleanability.
A study plan for Cleaning-in-Place, Sanitation & Hygienic Design in ICAR AICE-JRF/SRF
This plan follows where our questions actually fall, so the time goes where the marks are likely to be. It is our reading of the syllabus, not the exam body's weighting.
First, the heavy units (49% of the 67 questions): CIP circuit design and flow velocity (10, 15%); Detergents: alkalis, acids, sequestrants and surfactants (8, 12%); Sanitisers: heat, chlorine, iodophors, quaternary ammonium, peracetic acid (8, 12%); CIP systems: single-use, re-use and multi-tank (7, 10%).
Read the manual chapters for these first and do every worked question you can find on them.
Then the middle band: Biofilm control (6, 9%); Fouling and soil types in dairy plants (6, 9%); Hygienic design principles and 3-A and EHEDG guidance (6, 9%); Mechanism of soil removal: time, temperature, chemistry, mechanical action (6, 9%).
Aim for one sitting per unit, then mixed questions across them.
Then the lighter units: Cleaning of membranes, evaporators and dryers (5, 7%); Verification: ATP, swabs and visual inspection (5, 7%).
Learn the definitions, classifications and standard numbers; these units are more often recalled than worked.
Leave time for the hard ones: Verification: ATP, swabs and visual inspection (2 hard of 5), Sanitisers: heat, chlorine, iodophors, quaternary ammonium, peracetic acid (3 hard of 8), Biofilm control (2 hard of 6).
Come back to these after a first pass, untimed, and read every explanation, including for the options you rejected.
Bank the easy marks: Cleaning of membranes, evaporators and dryers (1 easy of 5); Biofilm control (1 easy of 6).
Do these early in revision so they are fast on the day.
Finish timed. Sit the subject as a timed set without notes, mark it, and send each wrong answer back to its unit above.