ICAR AIEEA-PG: Dairy Science (group 16) and Dairy Technology (group 17) is a postgraduate admission exam run by NTA for ICAR, for candidates in India. Computer-based, 2 hours, 120 multiple-choice questions, +4 for a correct answer and −1 for a wrong one (2026 bulletin). One paper per major subject group.

Source: icar.org.in.

Checked against the exam body's published information. Formats and fees change; confirm the current edition there before you book.

Dairy Refrigeration & Cold Chain in ICAR AIEEA-PG

Unit III: refrigeration and air conditioning, artificial refrigeration, compression systems, refrigeration accessories, and calculation of the size of a refrigeration machine.

Refrigeration systems, ice-bank and chilled-water plants, cold stores and the cold chain from farm to retail. The agricultural engineering track (refrigeration-cold-chain) gives the general theory.

Our 23 ICAR AIEEA-PG questions in this subject: 21 easy, 2 medium, 0 hard, across 12 units.

10 practice questions, worked

Choose an answer, then open the working. Each explanation says why the right answer is right and why the others are not.

These 10 were written to ICAR AIEEA-PG and are not shown on any other exam's page.

Question 1 · medium

What is the Carnot COP for refrigeration with evaporation at −10 °C and condensation at 35 °C?

  1. 5.85
  2. 6.85
  3. 3.50
  4. 0.22
Answer and working

A. 5.85

COP = 263.15 ÷ (308.15 − 263.15) = 5.85. 0.22 uses Celsius; 6.85 is the heat-pump Carnot COP; 3.50 is a meaningless ratio of Celsius values.

Question 2 · easy

A cold store's calculated load is 50 kW. With a 10% safety factor, what capacity is specified?

  1. 45 kW
  2. 60 kW
  3. 50 kW
  4. 55 kW
Answer and working

D. 55 kW

50 × 1.1 = 55 kW; 50 kW has no margin and 60 kW uses 20%.

Question 3 · easy

Why is the refrigerant vapour superheated slightly before entering the compressor?

  1. To lower compressor power to zero
  2. Protect the compressor
  3. To raise the condensing pressure
  4. To increase the refrigerant charge
Answer and working

B. Protect the compressor

Liquid slugging damages compressors.

Question 4 · easy

Which compressor type dominates large dairy ammonia plants?

  1. Diaphragm
  2. Scroll
  3. Capillary
  4. Screw
Answer and working

D. Screw

Screw compressors handle large volumes efficiently.

Question 5 · easy

The main purpose of a bulk milk cooler is to:

  1. Separate cream
  2. Ferment milk
  3. Pasteurise milk on the farm before sale
  4. Cool milk quickly after milking
Answer and working

D. Cool milk quickly after milking

Prompt cooling preserves raw milk quality.

Question 6 · easy

Hardening tunnels for ice cream typically use air at about:

  1. 0 °C
  2. +4 °C
  3. −5 °C
  4. −30 to −40 °C
Answer and working

D. −30 to −40 °C

Fast hardening keeps ice crystals small.

Question 7 · easy

Raw milk tankers are usually:

  1. Refrigerated to −18 °C
  2. Open-topped
  3. Insulated but not refrigerated
  4. Heated to keep milk warm in transit
Answer and working

C. Insulated but not refrigerated

Pre-cooled milk and short journeys limit warming.

Question 8 · easy

Relative humidity compares:

  1. Actual and saturation vapour pressure
  2. Dry-bulb and wet-bulb temperature
  3. Day and night temperature
  4. Air and water density
Answer and working

A. Actual and saturation vapour pressure

RH = partial pressure ÷ saturation pressure × 100.

Question 9 · easy

Direct-expansion bulk milk coolers evaporate refrigerant in:

  1. The milk itself
  2. A separate ice tank
  3. Plates on the tank base and walls
  4. The farm well
Answer and working

C. Plates on the tank base and walls

Ice-bank coolers use a separate ice store.

Question 10 · easy

Thicker insulation of the same material makes heat gain:

  1. Negative
  2. Larger
  3. Unchanged
  4. Smaller
Answer and working

D. Smaller

Heat flow falls as thickness rises, since U ≈ k ÷ thickness.

A study plan for Dairy Refrigeration & Cold Chain in ICAR AIEEA-PG

This plan follows where our questions actually fall, so the time goes where the marks are likely to be. It is our reading of the syllabus, not the exam body's weighting.

  1. First, the heavy units (52% of the 23 questions): Vapour compression cycle and coefficient of performance (5, 22%); Bulk milk coolers (3, 13%); Cooling load calculation for cold stores (2, 9%); Hardening rooms and frozen storage (2, 9%).

    Read the manual chapters for these first and do every worked question you can find on them.

  2. Then the middle band: Insulation and vapour barriers (2, 9%); Multi-pressure and ammonia systems (2, 9%); Psychrometry and air conditioning (2, 9%); Compressors, condensers, evaporators and expansion devices (1, 4%).

    Aim for one sitting per unit, then mixed questions across them.

  3. Then the lighter units: Ice-bank and chilled-water systems (1, 4%); Refrigerants and their environmental rules (1, 4%); Refrigerated transport and cold-chain monitoring (1, 4%); Vapour absorption refrigeration and heat pumps (1, 4%).

    Learn the definitions, classifications and standard numbers; these units are more often recalled than worked.

  4. Bank the easy marks: Cooling load calculation for cold stores (2 easy of 2); Hardening rooms and frozen storage (2 easy of 2).

    Do these early in revision so they are fast on the day.

  5. Finish timed. Sit the subject as a timed set without notes, mark it, and send each wrong answer back to its unit above.

Last updated · How Laisha writes and checks its pages · Report a mistake

Ask Laisha about this

Opens Laisha's chat with your question ready to send. Sign in or start free.

Unlock every question — ICAR AIEEA-PG Dairy Refrigeration & Cold Chain

US$10 a month · one price worldwide · cancel any time

  • Every practice question in this subject, with full working
  • Timed exam papers and progress by unit
  • Ask Laisha to explain any answer — up to 1,000 questions a month
Free or Smarter
FreeSmarter
Grow guides, pest pages, articlesRead allRead all
Ask Laisha5 a dayUp to 1,000 a month
Exam practiceThe sample on each pageEvery question, timed papers
Crop calendar and pest alerts—For your own fields
Calculators and tools—All
Uploads and reports—100 a month, real files
10 days free for every new account, no card.