ICAR AICE-JRF/SRF Dairy Refrigeration & Cold Chain: practice questions
ICAR AICE-JRF/SRF (PhD): Dairy Chemistry, Dairy Microbiology, Dairy Technology, Dairy Engineering · India · NTA for ICAR
Original practice questions written to the published syllabus · not past papers
10worked here, free
69written to this exam in this subject
12syllabus units
About ICAR AICE-JRF/SRF
ICAR AICE-JRF/SRF (PhD): Dairy Chemistry, Dairy Microbiology, Dairy Technology, Dairy Engineering is a PhD, fellowship and lectureship exam run by NTA for ICAR, for candidates in India.
Checked against the exam body's published information. Formats and fees change; confirm the current edition there before you book.
Dairy Refrigeration & Cold Chain in ICAR AICE-JRF/SRF
Unit 6: vapour compression components and types, theoretical and actual cycles, effect of operating parameters on COP, multi-pressure systems, vapour absorption, heat pumps, design of cold storage and air conditioning, cooling load calculation, psychrometry, equipment selection, insulation, vapour barriers and ice-bank tanks. Expect COP, TR, load and insulation calculations and system comparisons.
Refrigeration systems, ice-bank and chilled-water plants, cold stores and the cold chain from farm to retail. The agricultural engineering track (refrigeration-cold-chain) gives the general theory.
Our 69 ICAR AICE-JRF/SRF questions in this subject: 6 easy, 42 medium, 21 hard, across 12 units.
10 practice questions, worked
Choose an answer, then open the working. Each explanation says why the right answer is right and why the others are not.
These 10 were written to ICAR AICE-JRF/SRF and are not shown on any other exam's page.
Question 1 · easy
How many tons of refrigeration is 100 kW (1 TR = 3.517 kW)?
100.0 TR
12.0 TR
28.4 TR
351.7 TR
Answer and working
C. 28.4 TR
100 ÷ 3.517 = 28.4 TR. 351.7 multiplies; 100 ignores the conversion; 12 confuses with 12,000 Btu/h.
Question 2 · medium
A bulk milk cooler must cool 2,060 kg of milk from 35 to 4 °C in 3 hours (cp 3.9 kJ/kg K). What average refrigeration capacity is needed, ignoring losses?
23.1 kW
69.2 kW
3.0 kW
26.0 kW
Answer and working
A. 23.1 kW
Q = 2,060 × 3.9 × 31 = 249,054 kJ over 10,800 s = 23.1 kW. The others multiply by 3, use 35 K instead of the 31 K drop, or use 4 K.
Question 3 · medium
HFOs such as R1234yf are attractive because they have:
No flammability or pressure limits
High ozone depletion potential
Very low global warming potential
The same GWP as R404A
Answer and working
C. Very low global warming potential
They are low-GWP synthetic alternatives.
Question 4 · hard
In two-stage ammonia systems, intercooling between stages:
Adds water to the refrigerant
Removes the need for a condenser
Raises discharge temperature to aid oil return
Cools intermediate gas, cutting work
Answer and working
D. Cools intermediate gas, cutting work
Cooling the intermediate gas reduces work and discharge temperature.
Question 5 · medium
Ice water from an ice bank is typically at about:
0.5–1 °C
10 °C
4–6 °C
−10 °C
Answer and working
A. 0.5–1 °C
Melting ice holds the water near 0 °C.
Question 6 · easy
Pre-coolers using well water before the tank:
Replace cleaning
Reduce load
Freeze the milk
Increase energy use
Answer and working
B. Reduce load
Plate pre-coolers remove heat cheaply.
Question 7 · medium
High-hygiene filling rooms are supplied with filtered air at:
100% humidity
Positive pressure
Negative pressure
Zero ventilation
Answer and working
B. Positive pressure
Air flows outwards to less clean areas.
Question 8 · medium
Why are freezer store floors heated or ventilated underneath?
To warm products
To dry the insulation
To prevent frost heave
To save refrigeration energy
Answer and working
C. To prevent frost heave
Frozen soil expands and cracks floors.
Question 9 · easy
Stock rotation in frozen stores usually follows:
Last-in, first-out
First-expiry, first-out
Random picking
Largest pack first
Answer and working
B. First-expiry, first-out
Oldest dates are dispatched first.
Question 10 · medium
The ATP Agreement concerns:
Milk pricing
ATP bioluminescence testing
International carriage of perishable foods
Ammonia plant safety
Answer and working
C. International carriage of perishable foods
It classifies and tests refrigerated vehicles.
A study plan for Dairy Refrigeration & Cold Chain in ICAR AICE-JRF/SRF
This plan follows where our questions actually fall, so the time goes where the marks are likely to be. It is our reading of the syllabus, not the exam body's weighting.
First, the heavy units (38% of the 69 questions): Vapour compression cycle and coefficient of performance (8, 12%); Compressors, condensers, evaporators and expansion devices (6, 9%); Cooling load calculation for cold stores (6, 9%); Ice-bank and chilled-water systems (6, 9%).
Read the manual chapters for these first and do every worked question you can find on them.
Then the middle band: Refrigerants and their environmental rules (6, 9%); Refrigerated transport and cold-chain monitoring (6, 9%); Vapour absorption refrigeration and heat pumps (6, 9%); Bulk milk coolers (5, 7%).
Aim for one sitting per unit, then mixed questions across them.
Then the lighter units: Hardening rooms and frozen storage (5, 7%); Insulation and vapour barriers (5, 7%); Multi-pressure and ammonia systems (5, 7%); Psychrometry and air conditioning (5, 7%).
Learn the definitions, classifications and standard numbers; these units are more often recalled than worked.
Leave time for the hard ones: Hardening rooms and frozen storage (2 hard of 5), Multi-pressure and ammonia systems (2 hard of 5), Psychrometry and air conditioning (2 hard of 5).
Come back to these after a first pass, untimed, and read every explanation, including for the options you rejected.
Bank the easy marks: Bulk milk coolers (1 easy of 5); Hardening rooms and frozen storage (1 easy of 5).
Do these early in revision so they are fast on the day.
Finish timed. Sit the subject as a timed set without notes, mark it, and send each wrong answer back to its unit above.