Original practice questions written to the published syllabus · not past papersEngineers Canada Agricultural / Biosystems / Bioresource / Food Engineering examination syllabus is a licensing and registration exam run by Provincial and territorial regulators (syllabus by Engineers Canada), for candidates in Canada. Written confirmatory exams for graduates of non-CEAB programmes, assigned case by case.
Source: engineerscanada.ca.
Checked against the exam body's published information. Formats and fees change; confirm the current edition there before you book.
Conduction, convection, radiation, heat exchangers and diffusion — the physics of drying, cooling, freezing and cold-store walls.
Our 37 Engineers Canada Agricultural / Biosystems / Bioresource / Food Engineering examination syllabus questions in this subject: 0 easy, 11 medium, 26 hard, across 12 units.
Choose an answer, then open the working. Each explanation says why the right answer is right and why the others are not.
These 10 were written to Engineers Canada Agricultural / Biosystems / Bioresource / Food Engineering examination syllabus and are not shown on any other exam's page.
A vertical plate 0.5 m high loses heat by free convection to air (k = 0.026 W/m·K). For the stated temperature difference, Gr = 1.4 × 10⁸ and Pr = 0.71. Using Nu = 0.59 Ra^(1/4) for 10⁴ < Ra < 10⁹ and Nu = 0.10 Ra^(1/3) for 10⁹ < Ra < 10¹³, the average heat-transfer coefficient is closest to
A. 3.06 W/m²·K
Ra = Gr × Pr = 9.94 × 10⁷, in the laminar range, so Nu = 0.59 × (9.94 × 10⁷)^0.25 = 58.9 and h = 58.9 × 0.026/0.5 = 3.06 W/m²·K. The turbulent correlation gives 2.41 but does not apply below 10⁹; using Gr instead of Ra gives 3.34; 58.9 is Nu, not h.
A surface of emissivity 0.9 at 350 K exchanges radiation with large surroundings at 300 K. The linearised radiation heat-transfer coefficient h_r = εσ(T1 + T2)(T1² + T2²) is closest to
A. 7.05 W/m²·K
h_r = 0.9 × 5.67 × 10⁻⁸ × 650 × (350² + 300²) = 0.9 × 5.67 × 10⁻⁸ × 650 × 212,500 = 7.05 W/m²·K. Omitting ε gives 7.83; using °C gives a meaningless 0.035; 352 W/m²·K is the heat flux (h_r × 50 K), not the coefficient. h_r is of the same order as a natural-convection coefficient, so radiation is never negligible for surfaces in still air.
A steel sphere 20 mm in diameter (ρ = 7,800 kg/m³, c = 460 J/kg·K, k = 40 W/m·K) at 300 °C is cooled in air at 30 °C with h = 50 W/m²·K. The time for it to reach 100 °C is closest to
D. 323 s
Check Bi = hL_c/k = 50 × (0.02/6)/40 = 0.0042 < 0.1, so lumped. τ = ρcL_c/h = 7800 × 460 × 0.00333/50 = 239.2 s. t = τ ln[(T_i − T∞)/(T − T∞)] = 239.2 × ln(270/70) = 323 s. Forgetting to subtract T∞ gives 263 s; using r instead of r/3 gives 969 s; a linear (non-exponential) decay gives 177 s.
A dairy heat exchanger has a clean overall coefficient of 1,000 W/m²·K. A fouling resistance of 0.0002 m²·K/W is expected on each side. To deliver the same duty at the same LMTD, the area must be increased by about
C. 40%
Fouled: 1/U = 1/1000 + 2 × 0.0002 = 0.0014, so U = 714 W/m²·K. A ∝ 1/U, so A_fouled/A_clean = 1000/714 = 1.40: 40% more area. 20% counts fouling on one side only; 28.6% is the fall in U, not the rise in area. 0.04% reports the total fouling resistance (0.0004) as a percentage.
In a counterflow exchanger the hot fluid (C = 2,000 W/K) enters at 150 °C and the cold fluid (C = 4,000 W/K) enters at 30 °C; UA = 3,000 W/K. Using ε = [1 − exp(−NTU(1 − C_r))]/[1 − C_r exp(−NTU(1 − C_r))], the heat-transfer rate is closest to
D. 166 kW
C_min = 2,000 W/K (hot), C_r = 0.5, NTU = 3,000/2,000 = 1.5. ε = [1 − e^(−0.75)]/[1 − 0.5e^(−0.75)] = 0.6908. Q = ε C_min ΔT_max = 0.6908 × 2,000 × 120 = 166 kW. The parallel-flow relation gives 143 kW; the C_r = 0 relation gives 186 kW; using C_max in Q_max gives 332 kW, which exceeds what the hot fluid can give up.
In a condenser where N horizontal tubes are stacked in a vertical column, the average condensation coefficient per tube compared with a single tube is
C. lower, because condensate from upper tubes thickens the film on lower tubes
Nusselt's analysis gives an average coefficient that falls roughly as N^(−1/4) for a column of N tubes, since drainage from above thickens the film below. In practice splashing and ripples reduce the penalty somewhat, but the average is still below the single-tube value.
Gases A and B undergo equimolar counter-diffusion through a 50 mm path at 300 K. The partial pressure of A is 10 kPa at one end and 2 kPa at the other; D_AB = 1.5 × 10⁻⁵ m²/s and R = 8.314 kJ/kmol·K. The molar flux of A is
C. 9.62 × 10⁻⁷ kmol/m²·s
N_A = D(p_A1 − p_A2)/(RTL) = 1.5 × 10⁻⁵ × 8/(8.314 × 300 × 0.05) = 9.62 × 10⁻⁷ kmol/m²·s. Pressures in kPa with R in kJ/kmol·K give kmol/m²·s. Entering the pressures in Pa while keeping R in kJ/kmol·K gives 9.62 × 10⁻⁴, 1,000 times too large; using 27 °C instead of 300 K gives 1.07 × 10⁻⁵; entering L as 0.5 m gives 9.62 × 10⁻⁸.
A gas-phase diffusivity correlation gives D ∝ T^1.75 at constant pressure. If D = 2.5 × 10⁻⁵ m²/s at 300 K, its value at 350 K is closest to
B. 3.27 × 10⁻⁵ m²/s
D2 = D1(T2/T1)^1.75 = 2.5 × 10⁻⁵ × (350/300)^1.75 = 2.5 × 10⁻⁵ × 1.310 = 3.27 × 10⁻⁵ m²/s. A linear scaling gives 2.92; inverting the ratio gives 1.91; using °C gives 15.65.
For a counterflow heat exchanger with NTU = 3, which change raises the effectiveness the most?
D. Reducing the capacity ratio C_r from 1 to 0 at fixed NTU
At NTU = 3: counterflow with C_r = 1 gives ε = 3/4 = 0.750; with C_r = 0, ε = 1 − e⁻³ = 0.950, a gain of 0.200. Raising NTU to 3.5 at C_r = 1 gives 3.5/4.5 = 0.778, a gain of only 0.028. Parallel flow always lowers ε, and raising C_r lowers ε for a given NTU.
In a deep, fixed bed of grain dried with heated air entering at the bottom, a drying front moves upward through the bed. The practical consequence that operators manage by stirring the grain or limiting bed depth is that
C. the bottom layers are overdried while the top layers stay wet, giving a large moisture gradient
Air picks up moisture and cools as it rises, so drying occurs mainly in a zone near the inlet that moves upward. Grain below the front approaches equilibrium with hot inlet air and is overdried; grain above it is still wet. Exhaust air stays cool and humid until the front nears the top. Stirring, airflow reversal and shallow beds reduce the gradient.
This plan follows where our questions actually fall, so the time goes where the marks are likely to be. It is our reading of the syllabus, not the exam body's weighting.
Read the manual chapters for these first and do every worked question you can find on them.
Aim for one sitting per unit, then mixed questions across them.
Learn the definitions, classifications and standard numbers; these units are more often recalled than worked.
Come back to these after a first pass, untimed, and read every explanation, including for the options you rejected.
Last updated · How Laisha writes and checks its pages · Report a mistake
US$10 a month · one price worldwide · cancel any time
| Free | Smarter | |
|---|---|---|
| Grow guides, pest pages, articles | Read all | Read all |
| Ask Laisha | 5 a day | Up to 1,000 a month |
| Exam practice | The sample on each page | Every question, timed papers |
| Crop calendar and pest alerts | — | For your own fields |
| Calculators and tools | — | All |
| Uploads and reports | — | 100 a month, real files |
An AI operating system for agriculture: free guides, manuals and tools written for every country.