Original practice questions written to the published syllabus · not past papersGATE — Agricultural Engineering (AG) is a postgraduate admission exam run by IITs and IISc on rotation (2027: IIT Madras), for candidates in India. Computer-based, 3 hours, 100 marks (15 General Aptitude + 85 technical: 25 one-mark and 30 two-mark questions). MCQ, MSQ and NAT; negative marking on MCQ only (−1/3 for one-mark, −2/3 for two-mark); no partial credit on MSQ. On-screen virtual calculator.
Source: gate2027.iitm.ac.in.
Checked against the exam body's published information. Formats and fees change; confirm the current edition there before you book.
Heat and Mass Transfer sits in Section 7 (Dairy and Food Engineering). Composite-wall conduction and heat-exchanger calculations (LMTD, and increasingly effectiveness–NTU) appear almost every year as one- or two-mark numerical-answer questions. Also expected: critical radius of insulation, lumped-capacitance cooling time, fin heat flow and efficiency, Stefan–Boltzmann exchange with view factors, Nusselt/Reynolds/Prandtl definitions and the Dittus–Boelter equation, Fick's law, and drying-rate and moisture-basis conversions that overlap with Section 6. Watch units (kJ/h against W, °C against K in radiation) and the choice of characteristic length.
Conduction, convection, radiation, heat exchangers and diffusion — the physics of drying, cooling, freezing and cold-store walls.
Our 90 GATE questions in this subject: 21 easy, 55 medium, 14 hard, across 12 units.
Choose an answer, then open the working. Each explanation says why the right answer is right and why the others are not.
These 10 were written to GATE and are not shown on any other exam's page.
A spherical storage vessel has an inner radius of 0.5 m and is covered with 0.1 m of insulation (k = 0.04 W/m·K). The insulation inner surface is at −5 °C and its outer surface at 25 °C. The steady heat gain through the insulation is
D. 45.2 W
Spherical shell resistance R = (r2 − r1)/(4πk r1 r2) = 0.1/(4π × 0.04 × 0.5 × 0.6) = 0.6631 K/W, so Q = 30/0.6631 = 45.2 W. Using the plane-wall formula with the inner area gives 37.7 W and with the outer area 54.3 W; dropping r1 r2 from the denominator gives 151 W.
A cold-store wall of 150 m² consists of 230 mm brick (k = 0.7 W/m·K) and 100 mm insulation (k = 0.025 W/m·K). The outside air is at 40 °C with h = 20 W/m²·K and the inside air at 2 °C with h = 10 W/m²·K. The steady heat gain through the wall is closest to
B. 1,270 W
Resistance per m²: 1/20 + 0.23/0.7 + 0.10/0.025 + 1/10 = 0.05 + 0.3286 + 4.0 + 0.1 = 4.4786 m²·K/W. Flux q = 38/4.4786 = 8.485 W/m², and Q = 8.485 × 150 = 1,270 W. Ignoring the air films gives 1,320 W; leaving out the insulation gives 11,900 W; 8.5 W is the flux per square metre, not the total.
Water (ν = 1.0 × 10⁻⁶ m²/s) flows at 0.5 m/s through a tube of 25 mm internal diameter. The Reynolds number and flow regime are
D. 12,500; turbulent
Re = VD/ν = 0.5 × 0.025/1.0 × 10⁻⁶ = 12,500. Pipe flow is laminar below about 2,300, so this is turbulent. Entering D as 2.5 mm gives 1,250; using the radius gives 6,250; calling Re = 12,500 laminar confuses the pipe limit with the flat-plate limit of about 5 × 10⁵.
A small body obeying the lumped-capacitance model is plunged into a fluid. After a time equal to one time constant, its excess temperature (T − T∞) has fallen to about what fraction of the initial excess?
B. 0.368
θ/θ_i = exp(−t/τ) = e⁻¹ = 0.368 at t = τ. 0.632 is the fraction of the change already completed; 0.5 is the half-time (t = 0.693τ); 0.135 is reached after two time constants.
Soil initially at a uniform 20 °C (α = 5 × 10⁻⁷ m²/s) has its surface suddenly brought to 0 °C and held there. Treat the soil as a semi-infinite solid, with (T − T_s)/(T_i − T_s) = erf[x/(2√(αt))]. Given erf(0.24) = 0.266, erf(0.48) = 0.503 and erf(0.96) = 0.825, the temperature at 0.1 m depth after 6 hours is closest to
D. 10.1 °C
√(αt) = √(5 × 10⁻⁷ × 21,600) = 0.1039 m, so x/(2√(αt)) = 0.1/0.2078 = 0.48; erf(0.48) = 0.503. T = 0 + 0.503 × 20 = 10.1 °C. Forgetting the 2 gives the argument 0.96 and 16.5 °C; using 4 gives 0.24 and 5.3 °C; using 1 − erf gives 9.94 °C, which would be the temperature for heating from 0 °C towards 20 °C.
Oil (2.0 kg/s, c = 2.1 kJ/kg·K) is cooled by water (1.0 kg/s, c = 4.18 kJ/kg·K). The capacity ratio C_r and the fluid that has C_min are
D. C_r = 0.995; water has C_min
C_oil = 2.0 × 2.1 = 4.20 kW/K; C_water = 1.0 × 4.18 = 4.18 kW/K. Water has the smaller C, so C_r = 4.18/4.20 = 0.995. Comparing mass flows alone (0.50) or specific heats alone (0.502) is wrong: C is the product m·c.
As the excess temperature of a heated surface in a pool of saturated water is increased, the boiling regimes follow the order
A. natural convection → nucleate → transition → film boiling
At small ΔT_e heat moves by natural convection; bubbles then form at nucleation sites (nucleate boiling) up to the critical heat flux; beyond it, unstable vapour patches (transition boiling) reduce the flux to a minimum at the Leidenfrost point; above that, a stable vapour film covers the surface (film boiling).
Saturated steam condenses on a vertical plate 0.5 m high and 1 m wide whose surface is 10 °C below saturation. Liquid properties: ρ_l = 960 kg/m³, k_l = 0.68 W/m·K, μ_l = 2.8 × 10⁻⁴ Pa·s; h_fg = 2,257 kJ/kg; vapour density 0.6 kg/m³. Using h = 0.943[ρ_l(ρ_l − ρ_v)g h_fg k_l³/(μ_l L ΔT)]^(1/4), the condensate produced is closest to
A. 61.9 kg/h
h = 0.943 × [960 × 959.4 × 9.81 × 2.257 × 10⁶ × 0.68³/(2.8 × 10⁻⁴ × 0.5 × 10)]^0.25 = 7758 W/m²·K. Q = hAΔT = 7758 × 0.5 × 10 = 38788 W. Condensate = Q/h_fg = 38788/2.257 × 10⁶ = 0.01719 kg/s = 61.9 kg/h. Using the horizontal-tube constant gives 47.6; leaving ΔT out of Q = hAΔT gives 6.19; dividing by h_fg in kJ/kg gives a value 1,000 times too large. That value is 61,869 kg/h.
Water at 25 °C evaporates from the bottom of a narrow tube into dry air flowing across the top, 0.15 m above the water surface. Total pressure is 101.325 kPa, the vapour pressure of water is 3.17 kPa, D = 2.6 × 10⁻⁵ m²/s and R = 8.314 kJ/kmol·K. Treating the air as stagnant, the evaporation flux is closest to
C. 14.60 g/m²·h
Diffusion of A through stagnant B: N_A = [DP/(RTL)] ln[(P − p_A2)/(P − p_A1)] = [2.6 × 10⁻⁵ × 101.325/(8.314 × 298 × 0.15)] × ln(101.325/98.155) = 2.25 × 10⁻⁷ kmol/m²·s. × 18 kg/kmol × 1,000 g/kg × 3,600 s/h = 14.60 g/m²·h. The simple Fick form without the bulk-flow factor gives 14.37 (about 1.6% lower here, because the vapour is dilute); 0.0146 is a kg-to-g slip; using ln(P/p_A1) mixes up the partial pressures of the stagnant gas and gives 1591.
Grain with a moisture content of 20% (wet basis) has a dry-basis moisture content of
A. 25%
M_db = M_wb/(1 − M_wb) = 0.20/0.80 = 0.25 = 25%. 16.7% is the reverse conversion, M_wb = M_db/(1 + M_db), applied to 20%; 80% is the dry-matter fraction.
This plan follows where our questions actually fall, so the time goes where the marks are likely to be. It is our reading of the syllabus, not the exam body's weighting.
Read the manual chapters for these first and do every worked question you can find on them.
Aim for one sitting per unit, then mixed questions across them.
Learn the definitions, classifications and standard numbers; these units are more often recalled than worked.
Come back to these after a first pass, untimed, and read every explanation, including for the options you rejected.
Do these early in revision so they are fast on the day.
Last updated · How Laisha writes and checks its pages · Report a mistake
US$10 a month · one price worldwide · cancel any time
| Free | Smarter | |
|---|---|---|
| Grow guides, pest pages, articles | Read all | Read all |
| Ask Laisha | 5 a day | Up to 1,000 a month |
| Exam practice | The sample on each page | Every question, timed papers |
| Crop calendar and pest alerts | — | For your own fields |
| Calculators and tools | — | All |
| Uploads and reports | — | 100 a month, real files |
An AI operating system for agriculture: free guides, manuals and tools written for every country.