Original practice questions written to the published syllabus · not past papersICAR AIEEA-PG — Agricultural Engineering & Technology (Major Subject Group 10) is a postgraduate admission exam run by National Testing Agency for ICAR, for candidates in India. Computer-based, 120 minutes, 120 MCQs, +4 / −1, English only (2026 bulletin). One paper for the whole subject group.
Source: icar.org.in.
Checked against the exam body's published information. Formats and fees change; confirm the current edition there before you book.
Unit III (thermodynamics) and Unit VI (processing) ask single-answer MCQs: definitions of the dimensionless numbers, units of k, h, α and D, the physical meaning of the Biot and Fourier numbers, critical radius, counterflow versus parallel flow, Kirchhoff's law, black and grey bodies, and simple one-step calculations. Negative marking rewards knowing exact definitions.
Conduction, convection, radiation, heat exchangers and diffusion — the physics of drying, cooling, freezing and cold-store walls.
Our 63 ICAR AIEEA-PG questions in this subject: 31 easy, 32 medium, 0 hard, across 12 units.
Choose an answer, then open the working. Each explanation says why the right answer is right and why the others are not.
These 10 were written to ICAR AIEEA-PG and are not shown on any other exam's page.
A plane brick wall 0.2 m thick (k = 0.8 W/m·K) has an area of 10 m². Its faces are held at 35 °C and 5 °C. The steady heat flow through the wall is
A. 1,200 W
Q = kAΔT/L = 0.8 × 10 × 30 / 0.2 = 1,200 W. 120 W is the flux per square metre (W/m²) mistaken for the total; 12 W comes from entering the thickness as 20 cm instead of 0.2 m; 48 W comes from multiplying by L instead of dividing.
A steam pipe of outer radius 50 mm is covered with insulation (k = 0.05 W/m·K) to an outer radius of 100 mm. The inner and outer surfaces of the insulation are at 150 °C and 30 °C. The heat loss per metre length is closest to
B. 54.4 W/m
For a cylinder Q/L = 2πk(T1 − T2)/ln(r2/r1) = 2π × 0.05 × 120 / ln 2 = 54.4 W/m. Treating the layer as a plane wall of thickness 0.05 m with the inner area gives 37.7, with the outer area 75.4, and with the arithmetic-mean area 56.5 W/m; only the logarithmic-mean area makes the plane-wall formula exact.
A steel ball bearing 10 mm in diameter (k = 40 W/m·K) is cooled in air with h = 100 W/m²·K. The Biot number based on L_c = V/A_s is
B. 0.00417
For a sphere L_c = V/A_s = r/3 = 0.005/3 = 0.001667 m. Bi = hL_c/k = 100 × 0.001667/40 = 0.00417, well below 0.1, so the lumped model applies. Using r gives 0.0125; using D gives 0.025; 240 is the inverted ratio.
Adding fins to a heat-exchange surface is most worthwhile when the surface transfers heat to
C. a gas with a low convection coefficient
Fin effectiveness √(kP/(hA_c)) is large when h is small. Fins are therefore used on the air side of radiators, condensers and engine cylinders. With boiling, condensation or liquid metals, h is so high that the fin's own conduction resistance limits it and effectiveness is poor.
For a straight fin with an insulated tip, mL = 2.0. Its fin efficiency is closest to
A. 0.482
η_f = tanh(mL)/(mL) = 0.9640/2 = 0.482. 0.964 is tanh(mL) alone, the ratio of actual heat to that of an infinitely long fin; e^(−mL) = 0.135 is the tip excess-temperature ratio of an infinite fin; 1/(1 + mL) = 0.333 is not a fin relation at all.
Plate heat exchangers are the standard choice for milk pasteurisation mainly because they
B. give high heat-transfer coefficients in a compact unit, are easy to clean, and allow regeneration between hot and cold milk
Corrugated plates promote turbulence at modest velocity, giving high U; the pack can be opened for inspection and cleaned in place; and sections can be arranged for regeneration, where outgoing pasteurised milk heats incoming raw milk. Gasketed plate exchangers have pressure limits below shell-and-tube units, and they are normally run in counterflow.
The maximum possible heat-transfer rate used in defining heat-exchanger effectiveness is
A. C_min(T_h,in − T_c,in)
Only the fluid with the smaller heat-capacity rate can undergo the full temperature difference between the two inlets, which it would do in an infinitely long counterflow exchanger. Using C_max would require the other fluid to change temperature by more than the inlet difference, which violates the second law. UA × LMTD is the actual rate, not the maximum.
On the pool-boiling curve, the Leidenfrost point is
B. the point of minimum heat flux between transition and film boiling
The Leidenfrost point marks the minimum heat flux, where a stable vapour film first covers the surface; water drops skittering on a very hot plate show it. The maximum is the critical heat flux at the end of nucleate boiling.
The Sherwood number, Sh = h_m L/D_AB, is the mass-transfer analogue of the
B. Nusselt number
Sh is the dimensionless convective mass-transfer coefficient, as Nu is for heat. The Schmidt number Sc = ν/D is the analogue of Pr; the mass-transfer Biot number h_m L/D_solid uses the diffusivity inside the solid.
The Page thin-layer drying model is written as
B. MR = exp(−k tⁿ)
The Page model adds an empirical exponent n to the Lewis (Newton) model MR = exp(−kt). MR = a·exp(−kt) is the Henderson–Pabis model, and the last form is the first term of the diffusion solution for a slab.
This plan follows where our questions actually fall, so the time goes where the marks are likely to be. It is our reading of the syllabus, not the exam body's weighting.
Read the manual chapters for these first and do every worked question you can find on them.
Aim for one sitting per unit, then mixed questions across them.
Learn the definitions, classifications and standard numbers; these units are more often recalled than worked.
Do these early in revision so they are fast on the day.
Last updated · How Laisha writes and checks its pages · Report a mistake
US$10 a month · one price worldwide · cancel any time
| Free | Smarter | |
|---|---|---|
| Grow guides, pest pages, articles | Read all | Read all |
| Ask Laisha | 5 a day | Up to 1,000 a month |
| Exam practice | The sample on each page | Every question, timed papers |
| Crop calendar and pest alerts | — | For your own fields |
| Calculators and tools | — | All |
| Uploads and reports | — | 100 a month, real files |
An AI operating system for agriculture: free guides, manuals and tools written for every country.