ICAR AIEEA-PG — Agricultural Engineering & Technology (Major Subject Group 10) · India · National Testing Agency for ICAR
Original practice questions written to the published syllabus · not past papersICAR AIEEA-PG — Agricultural Engineering & Technology (Major Subject Group 10) is a postgraduate admission exam run by National Testing Agency for ICAR, for candidates in India. Computer-based, 120 minutes, 120 MCQs, +4 / −1, English only (2026 bulletin). One paper for the whole subject group.
Source: icar.org.in.
Checked against the exam body's published information. Formats and fees change; confirm the current edition there before you book.
Unit III sets single-answer MCQs across the whole subject: definitions (intensive/extensive, quasi-static, path functions), statements of the zeroth, first and second laws, Carnot efficiency and COP, polytropic-process relations, steam-table terms (dryness fraction, critical point, Mollier chart), air-standard efficiency formulas and comparisons, VCR components and the tonne of refrigeration, and psychrometric definitions. Negative marking rewards exact definitions and quick one-step calculations.
Energy, work, heat and the cycles behind engines, refrigerators and dryers.
Our 96 ICAR AIEEA-PG questions in this subject: 34 easy, 41 medium, 21 hard, across 9 units.
Choose an answer, then open the working. Each explanation says why the right answer is right and why the others are not.
These 10 were written to ICAR AIEEA-PG and are not shown on any other exam's page.
Which description fits a closed system (control mass)?
A. Energy may cross its boundary as heat or work, but no mass crosses it
A closed system has a fixed mass; heat and work can still cross its boundary. Allowing neither mass nor energy describes an isolated system, and mass flowing across the boundary (as in a pump) makes it an open system or control volume.
The zeroth law of thermodynamics provides the basis for
B. measuring temperature with a thermometer
The zeroth law says two bodies each in thermal equilibrium with a third are in equilibrium with each other; the thermometer is that third body, so the law makes temperature measurement meaningful. Energy conservation is the first law, the direction of heat flow is the second law, and the entropy reference is the third law.
A closed system receives 150 kJ of heat and does 60 kJ of work on its surroundings. The change in its internal energy is
C. +90 kJ
ΔU = Q − W = 150 − 60 = +90 kJ (heat in positive, work by the system positive). +210 kJ adds the work instead of subtracting it, −90 kJ reverses both signs, and +60 kJ confuses work with energy change.
Enthalpy is defined as
D. H = U + PV
Enthalpy is H = U + PV, the combination that appears in constant-pressure and flow processes. U − PV has no standard meaning, Q − W is the change in U from the first law, and U + TS is not a standard function (the Helmholtz function is U − TS).
Steam enters an adiabatic nozzle at negligible velocity and its enthalpy falls by 200 kJ/kg. The exit velocity is about
C. 632 m/s
V2 = √(2Δh) with Δh in J/kg: √(2 × 200 000) = 632 m/s. 447 m/s drops the factor 2, 20.0 m/s forgets to convert kJ to J, and 14.1 m/s makes both mistakes.
For a reversible process, the area under the process curve on a T–s diagram represents
D. the heat transferred during the process
For a reversible process δQ = T ds, so ∫T ds is the heat. Work is the area under a P–v curve; enthalpy and internal energy changes are not, in general, areas under a T–s line.
A heat-pump dryer delivers heat at 60 °C while drawing heat from air at 10 °C and has a measured COP of 3.5. Its second-law (exergetic) efficiency relative to a Carnot heat pump between the same temperatures is about
B. 53 %
COP_HP,Carnot = TH/(TH − TL) = 333.15/50 = 6.66; η_II = 3.5/6.66 = 53 %. 62 % uses the refrigerator Carnot COP TL/(TH − TL), 292 % uses Celsius temperatures (60/50), and 15 % is the Carnot engine efficiency between the two temperatures, not a heat-pump comparison.
On a Mollier (h–s) chart, constant-pressure lines inside the wet region are straight because
C. their slope ∂h/∂s at constant pressure equals the saturation temperature, which is constant there
From T ds = dh − v dP, at constant pressure dh/ds = T; in the wet region T = Tsat is constant, so the lines are straight. Enthalpy and entropy both change with quality during boiling, and the Mollier chart uses linear axes.
If the evaporator temperature of a cold store is lowered while the condensing temperature stays the same, the COP of the plant
B. decreases, because compressor work per kg rises and refrigerating effect falls
A lower evaporator pressure means a larger pressure ratio (more work per kg) and, usually, a smaller refrigerating effect, so COP falls — as the Carnot COP TL/(TH − TL) also shows. Suction vapour density actually falls, reducing capacity.
Air at 30 °C has a vapour pressure of 2.0 kPa. The saturation pressure of water at 30 °C is 4.247 kPa. The relative humidity is about
C. 47.1 %
φ = pv/psat = 2.0/4.247 = 47.1 %. 2.0 % divides by barometric pressure, 212 % inverts the ratio, and 46.0 % is the degree of saturation W/Ws, which is close to but not the same as relative humidity.
This plan follows where our questions actually fall, so the time goes where the marks are likely to be. It is our reading of the syllabus, not the exam body's weighting.
Read the manual chapters for these first and do every worked question you can find on them.
Aim for one sitting per unit, then mixed questions across them.
Learn the definitions, classifications and standard numbers; these units are more often recalled than worked.
Come back to these after a first pass, untimed, and read every explanation, including for the options you rejected.
Do these early in revision so they are fast on the day.
Last updated · How Laisha writes and checks its pages · Report a mistake
US$10 a month · one price worldwide · cancel any time
| Free | Smarter | |
|---|---|---|
| Grow guides, pest pages, articles | Read all | Read all |
| Ask Laisha | 5 a day | Up to 1,000 a month |
| Exam practice | The sample on each page | Every question, timed papers |
| Crop calendar and pest alerts | — | For your own fields |
| Calculators and tools | — | All |
| Uploads and reports | — | 100 a month, real files |
An AI operating system for agriculture: free guides, manuals and tools written for every country.