Energy, work, heat and the cycles behind engines, refrigerators and dryers.
Our 90 NCEES FE Other Disciplines questions in this subject: 20 easy, 47 medium, 23 hard, across 9 units.
Choose an answer, then open the working. Each explanation says why the right answer is right and why the others are not.
These 10 were written to NCEES FE Other Disciplines and are not shown on any other exam's page.
A closed system undergoes a cycle of four processes with heat transfers of +600, −250, +100 and −200 kJ. The work transfers in the first three processes are +150, +50 and −80 kJ. What is the work transfer in the fourth process?
A. +130 kJ
Over a cycle ΣQ = ΣW. ΣQ = 600 − 250 + 100 − 200 = 250 kJ. ΣW of the first three = 150 + 50 − 80 = 120 kJ, so W4 = 250 − 120 = +130 kJ. +250 kJ is the net heat, not the missing work; −130 kJ has the wrong sign; +370 kJ adds the known work instead of subtracting it.
An insulated tank holds 50 kg of water that a 3 kW electric heater must warm from 20 °C to 90 °C for washing dairy equipment (c = 4.18 kJ/kg·K; neglect losses). The heating time is about
B. 81.3 min
Q = m c ΔT = 50 × 4.18 × 70 = 14630 kJ; t = Q/P = 14630/3 = 4877 s = 81.3 min. 421.7 min uses the absolute final temperature (363.15 K) instead of the rise, 1.35 min treats hours as minutes, and 19.4 min uses c = 1 (a kcal habit) instead of 4.18 kJ/kg·K.
0.5 kg of air at 300 K is compressed isothermally and reversibly from 100 kPa to 500 kPa (R = 0.287 kJ/kg·K). The work input is
B. 69.3 kJ
W = mRT ln(P2/P1) = 0.5 × 0.287 × 300 × ln 5 = 69.3 kJ (input). 30.1 kJ uses log10 instead of ln, 172.2 kJ uses the pressure difference ratio (P2/P1 − 1) as though the relation were linear, and 431 kJ uses cv with that same linear error.
The air compressor of a sprayer takes 0.05 kg/s of air at 300 K and delivers it at 450 K while losing 2 kW of heat to the surroundings. Neglecting kinetic and potential energy changes (cp = 1.005 kJ/kg·K), the power input is
A. 9.54 kW
SFEE: Q − W = ṁ cp ΔT → −2 − W = 0.05 × 1.005 × 150 = 7.54, so W = −9.54 kW (input). 5.54 kW subtracts the heat loss instead of adding it, 7.54 kW ignores the heat loss, and 7.38 kW uses cv instead of cp for a flow process (0.05 × 0.718 × 150 + 2 = 7.38).
In the steady-flow energy equation, enthalpy rather than internal energy appears for each stream because
C. the fluid carries flow work Pv across the boundary in addition to its internal energy
Pushing fluid across the boundary requires flow work Pv per kg, and u + Pv = h. Internal energy is defined for flowing fluids too; kinetic energy is a separate term in the SFEE; and heat transfer need not be at constant pressure.
A pump raises the pressure of 20 kg/s of water (v = 0.001 m³/kg) by 300 kPa, with negligible changes in velocity, height and temperature. The ideal power required is
B. 6 kW
For an incompressible liquid w = vΔP = 0.001 × 300 = 0.3 kJ/kg; power = 20 × 0.3 = 6 kW. 6000 kW adds a spurious factor of 1000 (kPa × m³/kg already gives kJ/kg), 0.3 kW is the work per kg without the mass flow, and 0.6 kW is a misplaced decimal.
Which statement is the Clausius statement of the second law?
C. No cyclic device can transfer heat from a colder to a hotter body without some other effect
The Clausius statement concerns heat transfer from cold to hot needing an external effect (work). Converting all heat from one reservoir into work is Kelvin–Planck, net heat equals net work is the first law, and equilibrium with a third body is the zeroth law.
An air-standard dual cycle has compression ratio 14, constant-volume pressure ratio 1.5 and cut-off ratio 1.6 (γ = 1.4). Its efficiency is about
A. 62.5 %
η = 1 − (1/r^(γ−1)) × (rp rc^γ − 1)/[(rp − 1) + γ rp (rc − 1)] = 1 − 0.3480 × 1.0775 = 62.5 %. 65.2 % is the Otto value at r = 14, 61.4 % ignores the constant-volume part (pure Diesel), and 47.6 % leaves out the (rp − 1) term in the denominator.
On a pressure–enthalpy (p–h) chart, the ideal throttling process in a refrigeration cycle appears as
D. a vertical line at constant enthalpy
Throttling keeps h constant while pressure falls, so it is a vertical line on p–h axes. Horizontal lines are the evaporator and condenser, and the constant-entropy line is ideal compression.
Moist air at 30 °C and 101.325 kPa has a vapour pressure of 2.0 kPa (R of dry air = 0.287 kJ/kg·K). Its specific volume per kg of dry air is about
C. 0.876 m³/kg dry air
v = Ra T/(P − pv) = 0.287 × 303.15/99.325 = 0.876 m³/kg dry air. 0.859 uses total pressure instead of the dry-air partial pressure, 0.0867 uses °C, and 1.142 is the dry-air density, the inverse.
This plan follows where our questions actually fall, so the time goes where the marks are likely to be. It is our reading of the syllabus, not the exam body's weighting.
Read the manual chapters for these first and do every worked question you can find on them.
Aim for one sitting per unit, then mixed questions across them.
Learn the definitions, classifications and standard numbers; these units are more often recalled than worked.
Come back to these after a first pass, untimed, and read every explanation, including for the options you rejected.
Do these early in revision so they are fast on the day.
Last updated · How Laisha writes and checks its pages · Report a mistake
US$10 a month · one price worldwide · cancel any time
| Free | Smarter | |
|---|---|---|
| Grow guides, pest pages, articles | Read all | Read all |
| Ask Laisha | 5 a day | Up to 1,000 a month |
| Exam practice | The sample on each page | Every question, timed papers |
| Crop calendar and pest alerts | — | For your own fields |
| Calculators and tools | — | All |
| Uploads and reports | — | 100 a month, real files |
An AI operating system for agriculture: free guides, manuals and tools written for every country.