ICAR AIEEA-PG — Agricultural Engineering & Technology (Major Subject Group 10) · India · National Testing Agency for ICAR
Original practice questions written to the published syllabus · not past papersICAR AIEEA-PG — Agricultural Engineering & Technology (Major Subject Group 10) is a postgraduate admission exam run by National Testing Agency for ICAR, for candidates in India. Computer-based, 120 minutes, 120 MCQs, +4 / −1, English only (2026 bulletin). One paper for the whole subject group.
Source: icar.org.in.
Checked against the exam body's published information. Formats and fees change; confirm the current edition there before you book.
Recall of pump, valve and control-system types and of linkage control modes; at PhD level, load-sensing principles, hydrostatic transmissions, electro-hydraulic hitch control and design trade-offs.
Oil hydraulics on tractors and machines: pumps, motors, cylinders, valves and circuits.
Our 94 ICAR AIEEA-PG questions in this subject: 32 easy, 51 medium, 11 hard, across 9 units.
Choose an answer, then open the working. Each explanation says why the right answer is right and why the others are not.
These 10 were written to ICAR AIEEA-PG and are not shown on any other exam's page.
A loader's controls feel spongy and the boom bounces before settling. The oil in the reservoir looks milky-foamy. The most likely physical reason for the spongy response is
C. entrained air lowering the effective bulk modulus of the oil
Air bubbles make the oil far more compressible, so the cylinder moves before pressure builds and then oscillates; foamy oil is the visible sign. Water causes milky oil and corrosion but is not the main cause of compliance. A high relief setting does not make the system spongy, and cold oil reduces rather than increases effective pump delivery.
A pump with a displacement of 50 cm³/rev works against a pressure difference of 180 bar. Its mechanical (torque) efficiency is 90 %. The torque required at the pump shaft is
D. 159 N·m
Ideal torque = V × Δp/(2π) = 50 × 10⁻⁶ × 180 × 10⁵/(2π) = 143.2 N·m. Actual input torque = ideal/ηm = 159 N·m. 143 is the ideal torque with losses ignored; multiplying the ideal torque by ηm gives 129 (the motor rule, wrong for a pump); omitting 2π gives 1000.
An axial-piston swash-plate pump has 9 pistons of 16 mm diameter on a pitch-circle diameter of 60 mm. At a swash-plate angle of 18°, its displacement is
D. 35.3 cm³/rev
V = (π/4)d² × z × D × tan α = (π/4)(1.6 cm)² × 9 × 6.0 cm × tan 18° = 35.3 cm³/rev. Using sin α instead of tan α gives 33.6; using the pitch-circle radius gives 17.6; omitting tan α gives 108.6, which would correspond to tan α = 1 (a 45° swash angle).
In a hydrostatic transmission, a pump of 45 cm³/rev is driven at 2000 rev/min and feeds a fixed motor of 90 cm³/rev. The volumetric efficiency of the pump and of the motor is each 95 %. The motor speed is
C. 902.5 rev/min
Pump delivery = 45 × 2000 × 0.95 = 85500 cm³/min; motor speed = 85500 × 0.95/90 = 902.5 rev/min. Ignoring leakage gives 1000; applying only one efficiency gives 950.0; dividing by the efficiencies gives 1108.0.
Two work sections of a sectional mobile valve are connected in parallel. If the operator moves both spools fully at once, one lifting a light load and one a heavy load,
B. the lighter load moves first and takes most of the flow
In parallel sections each spool is fed from a common gallery, so pump pressure rises only to the lighter load's needs and that function takes the flow. Series sections pass oil from one to the next so both can move but pressures add; a tandem arrangement gives the upstream section priority.
For a direct-acting relief valve, the term 'pressure override' means
B. the difference between the full-flow pressure and the cracking pressure
Cracking pressure is where the valve first opens; as flow through it rises the spring compresses further, so pressure at full flow is higher. The difference is the override. Pilot-operated relief valves have much smaller override than direct-acting ones.
A fixed-displacement pump delivers 60 L/min. An operator holds the lift lever against a stalled cylinder so all the flow passes over a relief valve set at 175 bar. The rate of heat generation is
B. 17.5 kW
All the hydraulic power becomes heat: 175 × 60/600 = 17.5 kW. Using the MPa shortcut with bar gives 175; 1050 kW treats 60 L/min as 60 L/s; 1.75 is a factor-of-ten slip. This is why holding a lever at the end of stroke overheats the oil.
An uncompensated needle valve passes 20 L/min to a motor when the pressure drop across it is 25 bar. If load changes make the pressure drop across the valve 100 bar with the same opening, the flow becomes about
B. 40 L/min
Orifice flow varies with the square root of pressure drop: Q₂ = 20 × √(100/25) = 20 × 2 = 40 L/min. Assuming flow proportional to Δp gives 80; assuming it stays constant (as with a pressure-compensated valve) gives 20; 10 inverts the ratio, 20 × √(25/100). This load sensitivity is why compensated flow controls are used where speed must be steady.
In a closed-centre load-sensing system, with one function working at a load pressure of 120 bar and the pump margin set at 20 bar, the pump outlet pressure is about
C. 140 bar
A load-sensing pump keeps its outlet a fixed margin above the highest load pressure fed back through the signal line: 120 + 20 = 140 bar. 120 bar would leave no pressure drop to drive flow across the spool; 100 bar would be below the load; full limiter pressure would be a constant-pressure system, not load sensing.
ISO 730 defines categories (1, 2, 3, 4 and narrow variants) for the rear three-point linkage of agricultural tractors. What does the category mainly specify?
C. The hitch-pin diameters and the spacing of the linkage attachment points
Categories match tractor power ranges and fix the pin diameters and spacing so implements fit tractors of the same category. Pump pressure and control mode are not set by ISO 730, and quick couplers are covered by other standards such as ISO 5675 and ISO 16028.
This plan follows where our questions actually fall, so the time goes where the marks are likely to be. It is our reading of the syllabus, not the exam body's weighting.
Read the manual chapters for these first and do every worked question you can find on them.
Aim for one sitting per unit, then mixed questions across them.
Learn the definitions, classifications and standard numbers; these units are more often recalled than worked.
Come back to these after a first pass, untimed, and read every explanation, including for the options you rejected.
Do these early in revision so they are fast on the day.
Last updated · How Laisha writes and checks its pages · Report a mistake
US$10 a month · one price worldwide · cancel any time
| Free | Smarter | |
|---|---|---|
| Grow guides, pest pages, articles | Read all | Read all |
| Ask Laisha | 5 a day | Up to 1,000 a month |
| Exam practice | The sample on each page | Every question, timed papers |
| Crop calendar and pest alerts | — | For your own fields |
| Calculators and tools | — | All |
| Uploads and reports | — | 100 a month, real files |
An AI operating system for agriculture: free guides, manuals and tools written for every country.