Original practice questions written to the published syllabus · not past papersICAR AICE-JRF/SRF (PhD) — Agricultural Engineering subjects 38–43 is a PhD, fellowship and lectureship exam run by National Testing Agency for ICAR, for candidates in India. LAN-based computer test, 2 hours, 120 MCQs: 20 Part A (general knowledge and reasoning), 50 Part B (core group), 50 Part C (specialisation); four options.
Source: icar.org.in.
Checked against the exam body's published information. Formats and fees change; confirm the current edition there before you book.
Oil hydraulics on tractors and machines: pumps, motors, cylinders, valves and circuits.
Our 43 ICAR AICE-JRF/SRF questions in this subject: 1 easy, 20 medium, 22 hard, across 9 units.
Choose an answer, then open the working. Each explanation says why the right answer is right and why the others are not.
These 10 were written to ICAR AICE-JRF/SRF and are not shown on any other exam's page.
A pump of 32 cm³/rev displacement is tested at 1500 rev/min. At 200 bar it delivers 43.2 L/min and absorbs 17.0 kW at the shaft. Its mechanical (torque) efficiency is
C. 0.941
Theoretical flow = 32 × 1500/1000 = 48.0 L/min, so ηv = 43.2/48 = 0.900. Hydraulic output = 200 × 43.2/600 = 14.4 kW, so ηo = 14.4/17.0 = 0.847. ηm = ηo/ηv = 0.941. 0.847 is the overall efficiency, 0.900 the volumetric efficiency, and 0.762 wrongly multiplies them.
On a large tractor with a variable piston pump, a power-limiting (torque-limiting) pump control is fitted. Its function is to
A. reduce pump displacement as pressure rises so that p × Q stays below a set input power
A power limiter makes the pump follow an approximate constant-power curve, cutting displacement as pressure rises so the engine is not stalled. Holding a margin above load pressure is load sensing; sending flow over a relief is pressure limitation, not power limitation; keeping maximum displacement would overload the engine.
A cylinder with an 80 mm bore and a 56 mm rod is extended in a regenerative circuit with 40 L/min from the pump. The extension speed is
B. 0.271 m/s
In regenerative extension the rod-end oil joins the pump flow, so the effective area is the rod area: A = π(0.056)²/4 = 2.4630e-03 m²; v = 6.667 × 10⁻⁴/2.4630e-03 = 0.271 m/s. 0.133 is normal extension, 0.260 is normal retraction, and simply doubling normal speed gives 0.265.
The wings of a folding cultivator, lifted by series-connected master–slave cylinders, become progressively out of level over a day's work. The design feature intended to correct this is
C. a rephasing valve that lets both cylinders bottom out and re-synchronise at full stroke
Internal leakage across the pistons gradually changes the trapped oil volume between series cylinders, so they drift. Rephasing passages let oil bypass when a cylinder reaches the end of stroke, so holding the lever briefly at full lift brings both into step. Pressure, flow control or counterbalance valves do not restore the trapped volume.
A sharp-edged orifice of 4 mm diameter (Cd = 0.62) has a pressure drop of 50 bar. The oil density is 870 kg/m³. The flow through it is about
A. 50.1 L/min
Q = Cd·A·√(2Δp/ρ) = 0.62 × 1.257 × 10⁻⁵ × √(2 × 5 × 10⁶/870) = 0.62 × 1.257 × 10⁻⁵ × 107.2 = 8.353e-04 m³/s = 50.1 L/min. 0.835 is the L/s value written as L/min; omitting the square root gives an absurd 5373; omitting Cd gives 80.8.
A cylinder (80 mm bore, 56 mm rod) is speed-controlled by a meter-out valve on the rod-end line. The relief is set at 160 bar. With no external load, pressure in the rod end during extension can reach about
A. 314 bar
With no load, the cap-end force p × Ap must be balanced by rod-end pressure on the annulus: p_rod = 160 × Ap/Aa = 160 × 5027/2564 = 314 bar. This intensification can exceed the ratings of seals and hoses. Assuming 160 bar ignores the area ratio; 82 inverts it; using the rod area gives 327.
A 10 L bladder accumulator is precharged to 70 bar absolute and works isothermally between 100 bar and 200 bar absolute. The volume of oil it delivers between these pressures is
B. 3.50 L
p₀V₀ = 700 bar·L. Gas volume at 100 bar = 700/100 = 7.0 L; at 200 bar = 700/200 = 3.5 L. Oil delivered = 7.0 − 3.5 = 3.50 L. 5.00 ignores the precharge; 7.00 is the gas volume at 100 bar, not the oil delivered; 6.50 is the oil stored from precharge to 200 bar.
Compared with a load-sensing system, the main energy disadvantage of a closed-centre constant-pressure (pressure-compensated) system is that
D. pump pressure stays high, so functions needing low pressure throttle the difference as heat
A pressure-compensated pump holds a high pressure regardless of demand; a function working at low pressure must drop the difference across its valve, which becomes heat. Flow circulating at low pressure in neutral is an open-centre trait; constant-pressure systems can serve several functions and use a variable pump.
On small and medium tractors with a mechanical draft-control system, the draft signal is traditionally taken from
C. the compressive force in the top link acting on a calibrated spring
With a mounted implement the top link is usually in compression and the force rises with draft; a spring at its tractor end deflects and moves the control valve. Larger tractors sense lower-link forces, now with electronic load pins. Lift-cylinder pressure reflects implement weight more than draft, and engine-speed sensing is not the basis of draft control.
A tractor-mounted reversible plough lifts slowly, and the lift hesitates when the remote valves are used at the same time. The engine is at rated speed, the oil is at normal temperature and the level is correct. A flow test at the pump outlet shows rated flow at low pressure but much less at rated pressure. The most likely fault is
A. a worn pump with high internal leakage at pressure
A pump that delivers rated flow at low pressure but loses much of it at high pressure has internal leakage that rises with pressure: a worn pump. A blocked strainer reduces flow at all pressures with cavitation noise; an external cylinder leak would show oil outside; a stiff draft spring alters sensitivity, not pump delivery.
This plan follows where our questions actually fall, so the time goes where the marks are likely to be. It is our reading of the syllabus, not the exam body's weighting.
Read the manual chapters for these first and do every worked question you can find on them.
Aim for one sitting per unit, then mixed questions across them.
Learn the definitions, classifications and standard numbers; these units are more often recalled than worked.
Come back to these after a first pass, untimed, and read every explanation, including for the options you rejected.
Do these early in revision so they are fast on the day.
Last updated · How Laisha writes and checks its pages · Report a mistake
US$10 a month · one price worldwide · cancel any time
| Free | Smarter | |
|---|---|---|
| Grow guides, pest pages, articles | Read all | Read all |
| Ask Laisha | 5 a day | Up to 1,000 a month |
| Exam practice | The sample on each page | Every question, timed papers |
| Crop calendar and pest alerts | — | For your own fields |
| Calculators and tools | — | All |
| Uploads and reports | — | 100 a month, real files |
An AI operating system for agriculture: free guides, manuals and tools written for every country.