GATE — Agricultural Engineering (AG) · India · IITs and IISc on rotation (2027: IIT Madras)
Original practice questions written to the published syllabus · not past papersGATE — Agricultural Engineering (AG) is a postgraduate admission exam run by IITs and IISc on rotation (2027: IIT Madras), for candidates in India. Computer-based, 3 hours, 100 marks (15 General Aptitude + 85 technical: 25 one-mark and 30 two-mark questions). MCQ, MSQ and NAT; negative marking on MCQ only (−1/3 for one-mark, −2/3 for two-mark); no partial credit on MSQ. On-screen virtual calculator.
Source: gate2027.iitm.ac.in.
Checked against the exam body's published information. Formats and fees change; confirm the current edition there before you book.
Inside 'Tractors and Power Tillers': hydraulic force and power numericals, pump flow from displacement and efficiency, draft versus position control, open versus closed centre. NAT answers are sensitive to bar/MPa and L/min/m³/s slips.
Oil hydraulics on tractors and machines: pumps, motors, cylinders, valves and circuits.
Our 94 GATE questions in this subject: 32 easy, 51 medium, 11 hard, across 9 units.
Choose an answer, then open the working. Each explanation says why the right answer is right and why the others are not.
These 10 were written to GATE and are not shown on any other exam's page.
A log splitter uses a 100 mm bore, 70 mm rod cylinder at 200 bar. When the cylinder extends in regenerative mode, the maximum force available is
C. 77.0 kN
Pressure acts on both sides of the piston, so the net area is the rod area: F = 200 × 10⁵ × π(0.07)²/4 = 77.0 kN. The full piston area gives 157.1 kN, available only in normal extension; the annulus gives 80.1 kN, the retraction force; adding the areas has no basis. This is why regenerative circuits switch to normal extension when the wedge meets the log. Adding the areas gives 234.0 kN.
A cylinder must exert 50 kN on extension with a supply pressure of 140 bar, ignoring friction and back pressure. The minimum bore is about
C. 67.4 mm
A = F/p = 50000/(140 × 10⁵) = 3.571 × 10⁻³ m²; D = √(4A/π) = 67.4 mm. √(A/π) is the radius (33.7 mm); 3.57 is the area in a wrong unit; 213 mm comes from treating 140 bar as 14 bar. In practice the next larger standard bore and a friction allowance are chosen.
The lift cylinder that raises a tractor's rear three-point linkage is normally single-acting. This means that
A. oil pressure raises the linkage and the implement lowers under its own weight
A single-acting cylinder is powered in one direction only; on the lift it raises the linkage and the implement lowers by gravity, with a drop-rate valve controlling the speed. A double-acting cylinder has power both ways. Hitch categories concern pin sizes, and no tractor lift uses a spring to raise the load.
The cushions built into the ends of many hydraulic cylinders are intended to
A. slow the piston near the end of stroke by restricting the outgoing oil
A cushion spear or collar enters a pocket near the end cap, forcing the exhaust oil through a small adjustable orifice so the piston decelerates instead of striking the cap. It does not add force, lock the piston or filter the oil.
Compared with a direct-acting relief valve of the same size, a pilot-operated relief valve
D. has smaller pressure override and can be vented to unload the pump
A small pilot sets the pressure and controls a main poppet held by a light spring, so pressure changes little with flow, and connecting the vent port to tank unloads the pump. Direct-acting valves respond faster but override more. Pilot-operated valves are adjustable and suit large flows.
A sequence valve differs from a simple relief valve in that the sequence valve
D. has a pressurised working outlet, so it must be drained externally
Both are normally closed and opened by inlet pressure, but a relief valve's outlet goes to tank while a sequence valve's outlet is a working line at pressure, so its spring chamber must be drained externally. Normally open with outlet sensing describes a reducing valve; external pilot opening describes an unloading valve.
A circuit uses an accumulator and a fixed pump. When the accumulator is charged to its set pressure, an external pilot signal from the accumulator line opens a valve that returns pump flow to tank at low pressure. That valve is
A. an unloading valve
An unloading valve is normally closed and opened by an external pilot signal, letting the pump idle at low pressure while a check valve keeps the accumulator charged. Sequence and counterbalance valves are opened by their own inlet pressure, and a reducing valve is normally open and senses its outlet.
Which of the following is the main reason open-centre systems remain common on small and medium tractors?
C. They are simple and cheap, and gear pumps tolerate contaminated oil well
A fixed gear pump with open-centre valves is the lowest-cost system and the most forgiving of dirt. Load sensing is usually more efficient at part load, open-centre functions do interact when operated together, and instant full pressure is a feature of closed-centre constant-pressure systems.
In the design of a stationary industrial hydraulic power unit, a commonly used rule of thumb for an open-loop reservoir is a volume of about
D. two to three times the pump flow per minute
Fluid-power texts commonly suggest a reservoir of about two to three times the pump's flow per minute for industrial units, giving time for air release, settling and cooling. Mobile machines use much smaller tanks and rely on coolers. The largest cylinder's volume sets only the minimum working reserve, not the tank size.
On a tractor three-point linkage, the speed at which the implement descends when the lowering command is given is limited by
B. a drop-rate valve that throttles oil leaving the lift cylinder
The lift cylinder is single-acting, so the implement falls by gravity as oil leaves the cylinder; a drop-rate valve throttles that oil to set lowering speed. The relief valve limits maximum pressure, the pump does not push the linkage down, and top-link length sets implement pitch.
This plan follows where our questions actually fall, so the time goes where the marks are likely to be. It is our reading of the syllabus, not the exam body's weighting.
Read the manual chapters for these first and do every worked question you can find on them.
Aim for one sitting per unit, then mixed questions across them.
Learn the definitions, classifications and standard numbers; these units are more often recalled than worked.
Come back to these after a first pass, untimed, and read every explanation, including for the options you rejected.
Do these early in revision so they are fast on the day.
Last updated · How Laisha writes and checks its pages · Report a mistake
US$10 a month · one price worldwide · cancel any time
| Free | Smarter | |
|---|---|---|
| Grow guides, pest pages, articles | Read all | Read all |
| Ask Laisha | 5 a day | Up to 1,000 a month |
| Exam practice | The sample on each page | Every question, timed papers |
| Crop calendar and pest alerts | — | For your own fields |
| Calculators and tools | — | All |
| Uploads and reports | — | 100 a month, real files |
An AI operating system for agriculture: free guides, manuals and tools written for every country.