LAISHA
Open Laisha

GATE Hydraulic Drives & Controls: practice questions

GATE — Agricultural Engineering (AG) · India · IITs and IISc on rotation (2027: IIT Madras)

Original practice questions written to the published syllabus · not past papers
10worked here, free
94written to this exam in this subject
9syllabus units

About GATE

GATE — Agricultural Engineering (AG) is a postgraduate admission exam run by IITs and IISc on rotation (2027: IIT Madras), for candidates in India. Computer-based, 3 hours, 100 marks (15 General Aptitude + 85 technical: 25 one-mark and 30 two-mark questions). MCQ, MSQ and NAT; negative marking on MCQ only (−1/3 for one-mark, −2/3 for two-mark); no partial credit on MSQ. On-screen virtual calculator.

Source: gate2027.iitm.ac.in.

Checked against the exam body's published information. Formats and fees change; confirm the current edition there before you book.

Hydraulic Drives & Controls in GATE

Inside 'Tractors and Power Tillers': hydraulic force and power numericals, pump flow from displacement and efficiency, draft versus position control, open versus closed centre. NAT answers are sensitive to bar/MPa and L/min/m³/s slips.

Oil hydraulics on tractors and machines: pumps, motors, cylinders, valves and circuits.

Our 94 GATE questions in this subject: 32 easy, 51 medium, 11 hard, across 9 units.

10 practice questions, worked

Choose an answer, then open the working. Each explanation says why the right answer is right and why the others are not.

These 10 were written to GATE and are not shown on any other exam's page.

Question 1 · hard

A log splitter uses a 100 mm bore, 70 mm rod cylinder at 200 bar. When the cylinder extends in regenerative mode, the maximum force available is

  1. 157.1 kN
  2. 80.1 kN
  3. 77.0 kN
  4. 234.0 kN
Answer and working

C. 77.0 kN

Pressure acts on both sides of the piston, so the net area is the rod area: F = 200 × 10⁵ × π(0.07)²/4 = 77.0 kN. The full piston area gives 157.1 kN, available only in normal extension; the annulus gives 80.1 kN, the retraction force; adding the areas has no basis. This is why regenerative circuits switch to normal extension when the wedge meets the log. Adding the areas gives 234.0 kN.

Question 2 · medium

A cylinder must exert 50 kN on extension with a supply pressure of 140 bar, ignoring friction and back pressure. The minimum bore is about

  1. 33.7 mm
  2. 3.57 mm
  3. 67.4 mm
  4. 213 mm
Answer and working

C. 67.4 mm

A = F/p = 50000/(140 × 10⁵) = 3.571 × 10⁻³ m²; D = √(4A/π) = 67.4 mm. √(A/π) is the radius (33.7 mm); 3.57 is the area in a wrong unit; 213 mm comes from treating 140 bar as 14 bar. In practice the next larger standard bore and a friction allowance are chosen.

Question 3 · easy

The lift cylinder that raises a tractor's rear three-point linkage is normally single-acting. This means that

  1. oil pressure raises the linkage and the implement lowers under its own weight
  2. oil pressure both raises and lowers the linkage through two separate ports
  3. the cylinder can lift only one implement category without being changed
  4. a spring raises the linkage and oil pressure is used only for lowering it
Answer and working

A. oil pressure raises the linkage and the implement lowers under its own weight

A single-acting cylinder is powered in one direction only; on the lift it raises the linkage and the implement lowers by gravity, with a drop-rate valve controlling the speed. A double-acting cylinder has power both ways. Hitch categories concern pin sizes, and no tractor lift uses a spring to raise the load.

Question 4 · easy

The cushions built into the ends of many hydraulic cylinders are intended to

  1. slow the piston near the end of stroke by restricting the outgoing oil
  2. raise the force available at the end of the stroke for final clamping
  3. lock the piston at the end of its stroke when the pump is switched off
  4. filter the oil entering the cylinder to protect the piston and rod seals
Answer and working

A. slow the piston near the end of stroke by restricting the outgoing oil

A cushion spear or collar enters a pocket near the end cap, forcing the exhaust oil through a small adjustable orifice so the piston decelerates instead of striking the cap. It does not add force, lock the piston or filter the oil.

Question 5 · medium

Compared with a direct-acting relief valve of the same size, a pilot-operated relief valve

  1. responds faster to pressure spikes because it has no pilot stage
  2. has larger pressure override but handles much smaller flow rates
  3. cannot be adjusted once installed because its spring is internal
  4. has smaller pressure override and can be vented to unload the pump
Answer and working

D. has smaller pressure override and can be vented to unload the pump

A small pilot sets the pressure and controls a main poppet held by a light spring, so pressure changes little with flow, and connecting the vent port to tank unloads the pump. Direct-acting valves respond faster but override more. Pilot-operated valves are adjustable and suit large flows.

Question 6 · hard

A sequence valve differs from a simple relief valve in that the sequence valve

  1. is normally open and closes when the inlet pressure reaches its setting
  2. senses its outlet pressure and throttles to hold that outlet pressure constant
  3. is opened only by an external pilot signal and never by its own inlet pressure
  4. has a pressurised working outlet, so it must be drained externally
Answer and working

D. has a pressurised working outlet, so it must be drained externally

Both are normally closed and opened by inlet pressure, but a relief valve's outlet goes to tank while a sequence valve's outlet is a working line at pressure, so its spring chamber must be drained externally. Normally open with outlet sensing describes a reducing valve; external pilot opening describes an unloading valve.

Question 7 · medium

A circuit uses an accumulator and a fixed pump. When the accumulator is charged to its set pressure, an external pilot signal from the accumulator line opens a valve that returns pump flow to tank at low pressure. That valve is

  1. an unloading valve
  2. a sequence valve
  3. a reducing valve
  4. a counterbalance valve
Answer and working

A. an unloading valve

An unloading valve is normally closed and opened by an external pilot signal, letting the pump idle at low pressure while a check valve keeps the accumulator charged. Sequence and counterbalance valves are opened by their own inlet pressure, and a reducing valve is normally open and senses its outlet.

Question 8 · easy

Which of the following is the main reason open-centre systems remain common on small and medium tractors?

  1. They waste less energy than load sensing under every operating condition
  2. They allow several functions to run at once without any interaction
  3. They are simple and cheap, and gear pumps tolerate contaminated oil well
  4. They hold full system pressure instantly available at every valve
Answer and working

C. They are simple and cheap, and gear pumps tolerate contaminated oil well

A fixed gear pump with open-centre valves is the lowest-cost system and the most forgiving of dirt. Load sensing is usually more efficient at part load, open-centre functions do interact when operated together, and instant full pressure is a feature of closed-centre constant-pressure systems.

Question 9 · medium

In the design of a stationary industrial hydraulic power unit, a commonly used rule of thumb for an open-loop reservoir is a volume of about

  1. one tenth of the pump flow per minute
  2. the swept volume of the largest cylinder
  3. ten to twenty times the pump flow per minute
  4. two to three times the pump flow per minute
Answer and working

D. two to three times the pump flow per minute

Fluid-power texts commonly suggest a reservoir of about two to three times the pump's flow per minute for industrial units, giving time for air release, settling and cooling. Mobile machines use much smaller tanks and rely on coolers. The largest cylinder's volume sets only the minimum working reserve, not the tank size.

Question 10 · easy

On a tractor three-point linkage, the speed at which the implement descends when the lowering command is given is limited by

  1. the main relief valve setting of the tractor's hydraulic pump
  2. a drop-rate valve that throttles oil leaving the lift cylinder
  3. the speed of the pump, which pushes the implement down
  4. the top-link length set by the operator before work
Answer and working

B. a drop-rate valve that throttles oil leaving the lift cylinder

The lift cylinder is single-acting, so the implement falls by gravity as oil leaves the cylinder; a drop-rate valve throttles that oil to set lowering speed. The relief valve limits maximum pressure, the pump does not push the linkage down, and top-link length sets implement pitch.

A study plan for Hydraulic Drives & Controls in GATE

This plan follows where our questions actually fall, so the time goes where the marks are likely to be. It is our reading of the syllabus, not the exam body's weighting.

  1. First, the heavy units (41% of the 94 questions): Hydraulic cylinders (13, 14%); Hydraulic pumps: gear, vane and piston (13, 14%); Pressure relief and flow control valves (13, 14%).

    Read the manual chapters for these first and do every worked question you can find on them.

  2. Then the middle band: Tractor hydraulic systems (12, 13%); Hydraulic motors (10, 11%); Principles of fluid power (10, 11%).

    Aim for one sitting per unit, then mixed questions across them.

  3. Then the lighter units: Pressure drop and heat generation (9, 10%); Directional control valves (7, 7%); Open-centre, closed-centre and load-sensing circuits (7, 7%).

    Learn the definitions, classifications and standard numbers; these units are more often recalled than worked.

  4. Leave time for the hard ones: Hydraulic cylinders (3 hard of 13), Hydraulic pumps: gear, vane and piston (3 hard of 13), Pressure drop and heat generation (2 hard of 9).

    Come back to these after a first pass, untimed, and read every explanation, including for the options you rejected.

  5. Bank the easy marks: Principles of fluid power (6 easy of 10); Open-centre, closed-centre and load-sensing circuits (3 easy of 7).

    Do these early in revision so they are fast on the day.

  6. Finish timed. Sit the subject as a timed set without notes, mark it, and send each wrong answer back to its unit above.

Last updated · How Laisha writes and checks its pages · Report a mistake

Ask Laisha about this

Opens Laisha's chat with your question ready to send. Sign in or start free.

Unlock every question — GATE Hydraulic Drives & Controls

US$10 a month · one price worldwide · cancel any time

  • Every practice question in this subject, with full working
  • Timed exam papers and progress by unit
  • Ask Laisha to explain any answer — up to 1,000 questions a month
Free or Smarter
FreeSmarter
Grow guides, pest pages, articlesRead allRead all
Ask Laisha5 a dayUp to 1,000 a month
Exam practiceThe sample on each pageEvery question, timed papers
Crop calendar and pest alerts—For your own fields
Calculators and tools—All
Uploads and reports—100 a month, real files
10 days free for every new account, no card.