GATE — Agricultural Engineering (AG) · India · IITs and IISc on rotation (2027: IIT Madras)
Original practice questions written to the published syllabus · not past papersGATE — Agricultural Engineering (AG) is a postgraduate admission exam run by IITs and IISc on rotation (2027: IIT Madras), for candidates in India. Computer-based, 3 hours, 100 marks (15 General Aptitude + 85 technical: 25 one-mark and 30 two-mark questions). MCQ, MSQ and NAT; negative marking on MCQ only (−1/3 for one-mark, −2/3 for two-mark); no partial credit on MSQ. On-screen virtual calculator.
Source: gate2027.iitm.ac.in.
Checked against the exam body's published information. Formats and fees change; confirm the current edition there before you book.
Section 3 'Sources of Power': short calculations and NAT questions on power in wind (½ρAV³, Betz limit), PV fill factor and module area or efficiency, biogas plant sizing, and power from draught and speed. Unit handling (kgf, km/h, metric hp) decides marks.
Where the energy for farm work comes from, how much is available, and how mechanisation is measured.
Our 46 GATE questions in this subject: 14 easy, 14 medium, 18 hard, across 9 units.
Choose an answer, then open the working. Each explanation says why the right answer is right and why the others are not.
These 10 were written to GATE and are not shown on any other exam's page.
Standard agricultural engineering textbooks commonly take the mechanical power an adult worker can sustain over a working day as roughly:
A. 0.075–0.1 kW
About 0.1 hp, i.e. roughly 75 W, is the usual textbook figure for continuous work; planning studies often use about 0.05 kW. 0.75–1 kW is only reachable for a few seconds in a sprint, and 0.3–0.4 kW is closer to a draught animal's output.
A worker lifts 2400 litres of water through 5 m by hand in one hour. What is the useful (water-lifting) power output?
C. 32.7 W
P = mgh/t = 2400 × 9.81 × 5 / 3600 = 32.7 W (1 litre of water = 1 kg). Forgetting g gives 3.33 W; dividing by 60 instead of 3600 (minutes for seconds) gives 1,962 W, which no person can sustain. 0.33 W is a factor-of-ten slip on the 3.33 W value.
A diesel engine delivers 30 kW brake power while consuming 8 L/h of fuel (density 0.84 kg/L, calorific value 42 MJ/kg). What is its brake thermal efficiency?
B. 38.3%
Fuel energy rate = 8 × 0.84 × 42 = 282.24 MJ/h = 78.4 kW. Efficiency = 30/78.4 = 38.3%. Ignoring density gives 32.1%; dividing by density instead of multiplying gives 27.0%. 3.83% is a factor-of-ten slip.
The Betz limit states that the maximum fraction of the power in the wind that an ideal rotor can extract is:
B. 16/27, about 59.3%
Betz's analysis shows the maximum power coefficient is 16/27 ≈ 0.593, because air must keep flowing through the rotor. Real rotors achieve less.
If wind speed doubles, the power in the wind:
D. Increases eight times
Power ∝ V³, so 2³ = 8. Four times would be the effect of doubling rotor diameter (area ∝ D²).
Wind speed measured at 10 m is 5 m/s over open farmland. Using the power law with exponent 1/7, estimate the speed at a 30 m hub height.
B. 5.85 m/s
V30 = 5 × (30/10)^(1/7) = 5 × 1.1699 = 5.85 m/s. Scaling linearly with height gives 15 m/s; using a square root gives 8.66 m/s. The power gain is (1.170)³ ≈ 1.60 times.
The main constituents of biogas from a cattle-dung digester are:
A. Methane 50–70%, CO2 30–45%
Biogas is mainly CH4 and CO2 with small H2S and water vapour. The CO + H2 + N2 mix describes producer gas from gasification; 95% methane is upgraded biomethane or natural gas.
A digester yields 3.2 m³ of biogas per day with a calorific value of 20 MJ/m³. If a gas engine-generator converts 25% of the gas energy to electricity, how much electricity is produced per day?
D. 4.44 kWh
Gas energy = 3.2 × 20 = 64 MJ = 64/3.6 = 17.78 kWh; electricity = 0.25 × 17.78 = 4.44 kWh. 17.78 kWh is the fuel energy; 16.0 is MJ mislabelled as kWh. 71.1 kWh divides by the 25% efficiency instead of multiplying (17.78/0.25).
A block has 400 ha net sown area, 25 tractors of 30 kW, 10 power tillers of 9 kW, 150 electric motors of 5 kW, 60 diesel engines of 4 kW, 300 draught animals (0.38 kW each) and 900 workers (0.05 kW each). What is the farm power availability?
B. 4.97 kW/ha
Total = 750 + 90 + 750 + 240 + 114 + 45 = 1,989 kW; ÷ 400 ha = 4.97 kW/ha. Excluding people and animals gives 4.58; counting tractors only gives 1.88; dividing by a gross cropped area of 700 ha gives 2.84.
Why do mechanisation studies count a draught animal at a conventional figure of a few tenths of a kW rather than its peak output?
A. The factor represents sustained usable power over working hours, not a brief maximum
Animals and people can exceed their conventional figures briefly, but planning needs sustained power. Factors are conventions, differ between studies, and must be stated.
This plan follows where our questions actually fall, so the time goes where the marks are likely to be. It is our reading of the syllabus, not the exam body's weighting.
Read the manual chapters for these first and do every worked question you can find on them.
Aim for one sitting per unit, then mixed questions across them.
Learn the definitions, classifications and standard numbers; these units are more often recalled than worked.
Come back to these after a first pass, untimed, and read every explanation, including for the options you rejected.
Do these early in revision so they are fast on the day.
Last updated · How Laisha writes and checks its pages · Report a mistake
US$10 a month · one price worldwide · cancel any time
| Free | Smarter | |
|---|---|---|
| Grow guides, pest pages, articles | Read all | Read all |
| Ask Laisha | 5 a day | Up to 1,000 a month |
| Exam practice | The sample on each page | Every question, timed papers |
| Crop calendar and pest alerts | — | For your own fields |
| Calculators and tools | — | All |
| Uploads and reports | — | 100 a month, real files |
An AI operating system for agriculture: free guides, manuals and tools written for every country.