ASRB NET — Farm Machinery & Power / Land & Water Management Engineering / Agricultural Structures & Process Engineering · India · Agricultural Scientists Recruitment Board (ICAR)
Original practice questions written to the published syllabus · not past papersASRB NET — Farm Machinery & Power / Land & Water Management Engineering / Agricultural Structures & Process Engineering is a specialist certification exam run by Agricultural Scientists Recruitment Board (ICAR), for candidates in India. NET: 150 MCQs, 150 marks, 2 hours, −1/3 per wrong answer, English/Hindi, PG level. Combined NET/ARS/SMS/STO recruitment runs prelims, mains and interview.
Official site: pw.live.
We have not been able to confirm these details against the exam body's own specification, so fees, dates and pass marks are left out on purpose. Check the current format, eligibility, fees and dates on the official site.
Lecturer- and licence-level understanding of components and circuits, standards for linkage and couplers, efficiency and heat calculations, and the reasons behind design choices.
Oil hydraulics on tractors and machines: pumps, motors, cylinders, valves and circuits.
Our 43 ASRB NET questions in this subject: 1 easy, 20 medium, 22 hard, across 9 units.
Choose an answer, then open the working. Each explanation says why the right answer is right and why the others are not.
These 10 were written to ASRB NET and are not shown on any other exam's page.
A forestry contractor working beside a river is asked to use an environmentally acceptable hydraulic fluid. Under ISO 15380, a fluid classed HETG is based on
D. natural triglycerides, that is, vegetable oils
ISO 15380 defines HETG (triglycerides, vegetable oils), HEES (synthetic esters), HEPG (polyglycols) and HEPR (polyalphaolefins and related hydrocarbons). Vegetable-based HETG fluids biodegrade well but oxidise faster and are sensitive to water, so change intervals are often shorter.
An oil sample is reported with the ISO 4406 cleanliness code 20/18/15. Compared with a sample coded 17/15/12, the first sample has
B. roughly eight times as many particles in each size range
Each ISO 4406 scale number is a range of particle count per mL, and each step up roughly doubles the count. Three steps is 2³ ≈ 8 times as many particles. The numbers are not counts, not sizes, and three steps is not three times. The three positions refer to particles larger than 4, 6 and 14 µm(c).
A hydrostatic transmission with a variable pump and a fixed motor, operating at a fixed maximum pressure, is best described as a
A. constant-torque drive whose speed rises with pump displacement
With a fixed motor displacement, output torque = Vm·Δp/(2π) is fixed by the pressure limit, while speed follows pump flow; power therefore rises with speed. A fixed pump with a variable motor gives constant power, with torque falling as motor displacement is reduced to raise speed.
A fixed pump delivers 40 L/min with the relief valve set at 140 bar. A meter-in flow control lets 15 L/min reach a cylinder whose load needs 80 bar; the rest crosses the relief valve. The total power converted to heat is
A. 7.33 kW
Pump output = 140 × 40/600 = 9.33 kW (pump pressure is at relief setting). Useful power = 80 × 15/600 = 2.00 kW. Heat = 9.33 − 2.00 = 7.33 kW, made of 5.83 kW over the relief and 1.50 kW across the flow control. Each of those parts alone is an incomplete answer, and 9.33 ignores the useful work.
In a load-sensing valve bank serving several functions, the purpose of the shuttle valves in the signal network is to
C. pass the highest working load pressure to the pump's load-sensing control
Shuttle valves compare pairs of pressures and pass the higher; cascaded, they deliver the highest load pressure to the pump so it can supply every function. Averaging or passing the lowest would starve the most heavily loaded function. Steering priority is handled by a priority valve.
Mineral oil (ρ = 870 kg/m³, cp = 1.88 kJ/kg·K) passes through a relief valve from 140 bar to tank pressure without doing work. Assuming all the energy stays in the oil, its temperature rise is about
B. 8.6 °C
ΔT = Δp/(ρ·cp) = 140 × 10⁵/(870 × 1880) = 8.6 °C. Using cp in kJ instead of J gives 8560; a bar-to-pascal slip gives 0.86; using water's cp (4.18 kJ/kg·K) gives 3.8.
In an electronic hitch control system on a large tractor, the draft force is usually measured by
C. load pins, force sensors fitted in the lower-link mounting points
Electronic draft control measures lower-link force with load pins that sense shear or bending. A rockshaft position sensor provides the position signal; radar ground speed is used for slip control; the lever potentiometer gives the set-point, not the measured draft.
An electronic hitch has slip control enabled at 15 % wheel slip. While ploughing, slip rises to 20 % on a wet patch. The system responds by
A. raising the implement slightly to cut draft until slip falls back below the limit
Slip control compares driven-wheel speed with true ground speed (from radar or GNSS); when slip exceeds the set limit the hitch is raised a little to reduce draft. Lowering would raise draft and slip further. Differential lock and engine-speed management are separate functions.
Ride control on a tractor carrying a heavy mounted implement on the road works by
A. using the linkage as an active damper, moving it against the pitching motion of the tractor
Ride control senses pitching and moves the linkage, often against an accumulator or through valve control, to absorb and counteract the bounce, improving steering contact and comfort. A hydraulic lock transmits every shock, float would drop the implement, and engine-speed control is unrelated.
Which pump type is most tolerant of moderately contaminated oil and is therefore common on low-cost implements and small tractors?
C. External gear pump
Gear pumps have robust geometry and tolerate dirt better than piston or vane pumps, whose close-fitting pistons, shoes and vane tips are damaged quickly by particles. That, with low cost, is why they dominate open-centre systems. Contamination tolerance does not excuse poor filtration.
This plan follows where our questions actually fall, so the time goes where the marks are likely to be. It is our reading of the syllabus, not the exam body's weighting.
Read the manual chapters for these first and do every worked question you can find on them.
Aim for one sitting per unit, then mixed questions across them.
Learn the definitions, classifications and standard numbers; these units are more often recalled than worked.
Come back to these after a first pass, untimed, and read every explanation, including for the options you rejected.
Do these early in revision so they are fast on the day.
Last updated · How Laisha writes and checks its pages · Report a mistake
US$10 a month · one price worldwide · cancel any time
| Free | Smarter | |
|---|---|---|
| Grow guides, pest pages, articles | Read all | Read all |
| Ask Laisha | 5 a day | Up to 1,000 a month |
| Exam practice | The sample on each page | Every question, timed papers |
| Crop calendar and pest alerts | — | For your own fields |
| Calculators and tools | — | All |
| Uploads and reports | — | 100 a month, real files |
An AI operating system for agriculture: free guides, manuals and tools written for every country.