ICAR AIEEA-PG: Dairy Science (group 16) and Dairy Technology (group 17) is a postgraduate admission exam run by NTA for ICAR, for candidates in India. Computer-based, 2 hours, 120 multiple-choice questions, +4 for a correct answer and −1 for a wrong one (2026 bulletin). One paper per major subject group.

Source: icar.org.in.

Checked against the exam body's published information. Formats and fees change; confirm the current edition there before you book.

Dairy Plant Utilities & Energy Management in ICAR AIEEA-PG

Group 18 Unit II: equipment for steam generation, compressed air, refrigeration, water and wastewater treatment, and energy audit; group 17 Unit III: thermodynamics and electrical engineering fundamentals.

Steam, water, compressed air and electricity in the milk plant, and how to audit and cut energy and water use.

Our 48 ICAR AIEEA-PG questions in this subject: 18 easy, 30 medium, 0 hard, across 10 units.

10 practice questions, worked

Choose an answer, then open the working. Each explanation says why the right answer is right and why the others are not.

These 10 were written to ICAR AIEEA-PG and are not shown on any other exam's page.

Question 1 · easy

A boiler produces 2,000 kg of steam while burning 140 kg of oil. What is its evaporation ratio?

  1. 1,860
  2. 14.3
  3. 0.07
  4. 1,429
Answer and working

B. 14.3

Evaporation ratio = steam ÷ fuel = 2,000 ÷ 140 = 14.3 kg of steam per kg of fuel.

Question 2 · medium

The power factor of a 400 kW load is raised from 0.8 to 0.95. What is the new apparent power?

  1. 421 kVA
  2. 500 kVA
  3. 380 kVA
  4. 475 kVA
Answer and working

A. 421 kVA

New kVA = 400 ÷ 0.95 = 421 kVA, down from 500. 380 multiplies; 475 applies the PF to the old kVA.

Question 3 · easy

A pump delivers 100 m³/h at 1,450 rpm. By the affinity laws, what flow does it give at 1,160 rpm?

  1. 64 m³/h
  2. 51 m³/h
  3. 80 m³/h
  4. 125 m³/h
Answer and working

C. 80 m³/h

Flow ∝ speed: 100 × 1,160 ÷ 1,450 = 80 m³/h. 64 and 51 apply the square and cube laws.

Question 4 · easy

A heat pump delivers 300 kW of heat using 75 kW of electricity. What is its heating COP?

  1. 3.0
  2. 4.0
  3. 5.0
  4. 0.25
Answer and working

B. 4.0

Heating COP = 300 ÷ 75 = 4.0. 3.0 would be the cooling COP (225 ÷ 75).

Question 5 · easy

In which boiler do hot combustion gases pass through tubes surrounded by water?

  1. Fire-tube boiler
  2. Electrode boiler
  3. Water-tube boiler with steam and mud drums
  4. Thermic fluid heater with oil coils
Answer and working

A. Fire-tube boiler

Shell or fire-tube boilers carry gases in tubes inside a water-filled shell.

Question 6 · medium

What does a boiler economiser do?

  1. Heats feed water with flue gas
  2. Heats combustion air using steam bled from the drum
  3. Superheats steam leaving the boiler
  4. Cools blowdown before discharge
Answer and working

A. Heats feed water with flue gas

Recovering flue gas heat into feed water lowers stack temperature and raises efficiency.

Question 7 · medium

Why are chlorides in process water a concern in dairies?

  1. They pit and crack stainless steel
  2. They lower water density
  3. They feed lactic acid bacteria
  4. They make water hard and form scale
Answer and working

A. They pit and crack stainless steel

Chloride attacks the passive layer, causing pitting and stress corrosion cracking, worse when hot.

Question 8 · easy

How is power factor defined?

  1. kW ÷ kVA
  2. kW × kVA
  3. kVAr ÷ kW
  4. kVA ÷ kW
Answer and working

A. kW ÷ kVA

Power factor = real power ÷ apparent power = cos φ.

Question 9 · medium

What is the typical methane content of biogas from dairy effluent?

  1. 90–99%
  2. 10–20%
  3. 30–40%
  4. 60–70%
Answer and working

D. 60–70%

The rest is mainly CO₂ with traces of H₂S and water vapour.

Question 10 · medium

What does 'fit-for-purpose' mean in water reuse?

  1. Discharging all used water
  2. Using only municipal water
  3. Matching quality to use
  4. Reusing all water as drinking water
Answer and working

C. Matching quality to use

Each recovered stream is treated and monitored to match the quality its use needs.

A study plan for Dairy Plant Utilities & Energy Management in ICAR AIEEA-PG

This plan follows where our questions actually fall, so the time goes where the marks are likely to be. It is our reading of the syllabus, not the exam body's weighting.

  1. First, the heavy units (56% of the 48 questions): Boilers: types, fittings, mountings and efficiency (8, 17%); Electrical supply and power factor (7, 15%); Steam distribution and condensate recovery (7, 15%); Renewable energy in dairy plants: solar thermal, biogas (5, 10%).

    Read the manual chapters for these first and do every worked question you can find on them.

  2. Then the middle band: Boiler and pressure-vessel safety rules (4, 8%); Energy audits (4, 8%); Heat recovery and cogeneration (4, 8%); Water conservation and reuse (4, 8%).

    Aim for one sitting per unit, then mixed questions across them.

  3. Then the lighter units: Water supply, treatment and quality for dairy use (4, 8%); Compressed air systems (1, 2%).

    Learn the definitions, classifications and standard numbers; these units are more often recalled than worked.

  4. Bank the easy marks: Boiler and pressure-vessel safety rules (2 easy of 4); Heat recovery and cogeneration (2 easy of 4).

    Do these early in revision so they are fast on the day.

  5. Finish timed. Sit the subject as a timed set without notes, mark it, and send each wrong answer back to its unit above.

Last updated · How Laisha writes and checks its pages · Report a mistake

Ask Laisha about this

Opens Laisha's chat with your question ready to send. Sign in or start free.

Unlock every question — ICAR AIEEA-PG Dairy Plant Utilities & Energy Management

US$10 a month · one price worldwide · cancel any time

  • Every practice question in this subject, with full working
  • Timed exam papers and progress by unit
  • Ask Laisha to explain any answer — up to 1,000 questions a month
Free or Smarter
FreeSmarter
Grow guides, pest pages, articlesRead allRead all
Ask Laisha5 a dayUp to 1,000 a month
Exam practiceThe sample on each pageEvery question, timed papers
Crop calendar and pest alerts—For your own fields
Calculators and tools—All
Uploads and reports—100 a month, real files
10 days free for every new account, no card.