Tamil Nadu PSC — Agricultural Engineering (Code 164, degree standard) · India · Tamil Nadu Public Service Commission
Original practice questions written to the published syllabus · not past papersTamil Nadu PSC — Agricultural Engineering (Code 164, degree standard) is a government recruitment exam run by Tamil Nadu Public Service Commission, for candidates in India. Degree-standard subject paper (for posts such as Assistant Engineer (Agri)).
Source: tnpsc.gov.in.
Checked against the exam body's published information. Formats and fees change; confirm the current edition there before you book.
Managing water at the scale of reservoirs, canals and river basins, including floods and farmer participation.
Our 43 Tamil Nadu PSC questions in this subject: 25 easy, 12 medium, 6 hard, across 9 units.
Choose an answer, then open the working. Each explanation says why the right answer is right and why the others are not.
These 10 were written to Tamil Nadu PSC and are not shown on any other exam's page.
Contours 5 m apart enclose 2.0 km² and 3.2 km² of a reservoir basin. Using the cone (prismoidal) formula, what is the storage between them?
A. 12.88 Mm³
Cone formula: ΔV = (h/3)(A1 + A2 + √(A1A2)) = (5/3)(2.0 + 3.2 + 2.53) × 10⁶ = 12.88 Mm³. 13.00 is the trapezoidal formula, which slightly overestimates; 26.00 forgets to divide by 2 in the trapezoidal formula; 6.44 halves the right answer.
How does a barrage differ from a weir?
C. A barrage has a low crest and controls the pond level with gates across its whole length
A weir raises water with a fixed crest (sometimes with small shutters); a barrage has a low crest and gates over the full width, giving better control and less afflux. Neither is a storage dam, and both are common on alluvium.
What do guide banks at a weir or barrage do?
B. They confine the river to the waterway of the structure and guide flow through it
Guide banks (Bell's bunds) train the river through the structure and protect its flanks from outflanking. Diverting flow is the head regulator's job; holding back the pond is the weir's.
Why do designers prefer proportional or slightly sub-proportional outlets near the tail of a distributary?
C. So that when the distributary runs low, head outlets do not take more than their share and starve the tail
Fair sharing of fluctuations protects the tail. A hyper-proportional outlet upstream takes extra when levels rise and the effect cascades. No outlet delivers when the channel is closed; downstream control would make the outlet non-modular.
Under warabandi, how is each farmer's turn on a watercourse fixed?
C. A fixed time on a fixed day of a weekly cycle, in proportion to the farmer's landholding
Warabandi gives the whole outlet flow for a time proportional to area, at a fixed day and hour in a 7-day cycle. Application-based allotment is closer to Maharashtra's shejpali; equal hours ignores holding size.
Using Ryves' formula Q = C·A^(2/3) with C = 6.8 (Q in m³/s, A in km²), what is the peak flood from a 500 km² catchment?
D. About 428 m³/s
Q = 6.8 × 500^(2/3) = 6.8 × 63.0 = 428 m³/s. 719 uses Dickens' exponent 3/4; 3,400 uses A to the power 1; 152 uses A^0.5.
Which measure reduces flood damage to a house without changing the flood itself?
A. Raising the plinth above the expected flood level
Flood proofing, such as raising plinths, protects property against a given flood. Detention, channel widening and levees all change the flood flow or level.
Under India's classification by culturable command area, a scheme with a CCA of 1,500 ha is
C. a minor irrigation project
India: minor below 2,000 ha CCA, medium 2,000–10,000 ha, major above 10,000 ha. Command area development is a programme, not a size class.
A tank's 15 km² catchment receives 900 mm of rain, with a runoff coefficient of 0.25. After 30% losses to evaporation and seepage, the crops need a delta of 0.5 m. About how much area can be irrigated?
D. About 470 ha
Yield = 15 × 10⁶ × 0.9 × 0.25 = 3.375 Mm³; usable = 3.375 × 0.7 = 2.36 Mm³; area = 2.36 × 10⁶ ÷ 0.5 = 4.73 × 10⁶ m² ≈ 473 ha. 675 ignores losses; 1,890 omits the runoff coefficient; 330 applies the loss twice.
What is the function of the sluice in an irrigation tank?
B. To release controlled amounts of stored water to the command
The sluice is the controlled outlet to the command. Flood passing is the surplus weir; supply is the supply channel.
This plan follows where our questions actually fall, so the time goes where the marks are likely to be. It is our reading of the syllabus, not the exam body's weighting.
Read the manual chapters for these first and do every worked question you can find on them.
Aim for one sitting per unit, then mixed questions across them.
Learn the definitions, classifications and standard numbers; these units are more often recalled than worked.
Come back to these after a first pass, untimed, and read every explanation, including for the options you rejected.
Do these early in revision so they are fast on the day.
Last updated · How Laisha writes and checks its pages · Report a mistake
US$10 a month · one price worldwide · cancel any time
| Free | Smarter | |
|---|---|---|
| Grow guides, pest pages, articles | Read all | Read all |
| Ask Laisha | 5 a day | Up to 1,000 a month |
| Exam practice | The sample on each page | Every question, timed papers |
| Crop calendar and pest alerts | — | For your own fields |
| Calculators and tools | — | All |
| Uploads and reports | — | 100 a month, real files |
An AI operating system for agriculture: free guides, manuals and tools written for every country.