ICAR AICE-JRF/SRF Food Analysis: Proximate, Chemical & Instrumental Methods: practice questions
ICAR AICE-JRF/SRF (PhD) — Food Processing Technology, Food Safety & Quality, Processing and Food Engineering · India · ICAR through the National Testing Agency
Original practice questions written to the published syllabus · not past papers
10worked here, free
69written to this exam in this subject
15syllabus units
About ICAR AICE-JRF/SRF
ICAR AICE-JRF/SRF (PhD) — Food Processing Technology, Food Safety & Quality, Processing and Food Engineering is a PhD, fellowship and lectureship exam run by ICAR through the National Testing Agency, for candidates in India. Computer-based, multiple choice.
Checked against the exam body's published information. Formats and fees change; confirm the current edition there before you book.
Food Analysis: Proximate, Chemical & Instrumental Methods in ICAR AICE-JRF/SRF
35.b Unit 6 names spectroscopy (visible, IR, UV), chromatography (TLC, GLC, HPLC, gel filtration, ion exchange, affinity), electrophoresis (PAGE, SDS-PAGE), isoelectric focusing, ultracentrifugation and potentiometry; 35.b Unit 1 names ISO/IEC 17025 and NABL accreditation. Expect deeper questions on MS/MS, matrix effects, validation statistics and quality control.
How a food laboratory measures what is in a food: sampling, proximate analysis, official methods, and the instruments — spectroscopy, chromatography, mass spectrometry and electrophoresis — that a food analyst runs. It is the core of the food analyst qualification in countries that license analysts.
Our 69 ICAR AICE-JRF/SRF questions in this subject: 5 easy, 49 medium, 15 hard, across 15 units.
10 practice questions, worked
Choose an answer, then open the working. Each explanation says why the right answer is right and why the others are not.
These 10 were written to ICAR AICE-JRF/SRF and are not shown on any other exam's page.
Question 1 · medium
Karl Fischer titration is preferred for low-moisture products because it
measures all volatile compounds as water
needs no reagents at all
measures water specifically
works only above 50 % moisture
Answer and working
C. measures water specifically
The iodine–sulphur dioxide reaction is specific to water; oven methods count all volatiles.
Question 2 · medium
Before HPLC of vitamins A and E in fatty foods, samples are usually
saponified
ashed at 550 °C
digested with sulphuric acid
fermented with yeast
Answer and working
A. saponified
Alkaline saponification removes triglycerides and releases the vitamins for extraction.
Question 3 · medium
Fluorescence methods are generally more sensitive than absorption methods because
fluorescence uses higher light intensity in every case
all molecules fluoresce strongly
fluorescence needs no wavelength selection
emitted light is measured against a dark background
Answer and working
D. emitted light is measured against a dark background
A small signal on a dark background is easier to measure than a small decrease in a bright beam.
Question 4 · medium
Near-infrared analysers for grain protein rely on
a single absorption band unique to protein in every grain sample
direct measurement of nitrogen atoms
multivariate calibration against reference methods
the Beer–Lambert law with no calibration
Answer and working
C. multivariate calibration against reference methods
NIR bands overlap, so chemometric models (e.g. PLS) are built from samples analysed by Kjeldahl or Dumas.
Question 5 · medium
In UV-visible spectrophotometers, the lamp used for the ultraviolet region is usually a
tungsten lamp
sodium lamp
hollow-cathode lamp
deuterium lamp
Answer and working
D. deuterium lamp
Deuterium for UV, tungsten-halogen for visible; hollow-cathode lamps are for AAS.
Question 6 · medium
Raman spectroscopy is attractive for food authenticity partly because it is
little affected by water
unable to measure solids
dependent on radioactive sources
only usable with destroyed samples
Answer and working
A. little affected by water
Water is a weak Raman scatterer, so aqueous foods can be measured; it is also useful through packaging.
Question 7 · medium
Mercury is commonly determined by
flame emission photometry
Soxhlet extraction
biuret colorimetry
cold-vapour atomic absorption
Answer and working
D. cold-vapour atomic absorption
Mercury is reduced to elemental vapour and measured without a flame; hydride generation is used for arsenic and selenium.
Question 8 · medium
Triple-quadrupole MS operated in multiple reaction monitoring mode is valued for residue analysis because it
identifies unknown compounds by library search of full-scan spectra
monitors specific precursor-to-product transitions
measures elemental isotopes
needs no chromatography
Answer and working
B. monitors specific precursor-to-product transitions
MRM gives high selectivity and sensitivity in complex matrices.
Question 9 · hard
A blank's standard deviation is 0.02 absorbance units and the calibration slope 0.5 absorbance per mg/L. Using LOQ ≈ 10σ/S, the limit of quantification is
0.132 mg/L
0.01 mg/L
0.40 mg/L
2.50 mg/L
Answer and working
C. 0.40 mg/L
LOQ = 10 × 0.02/0.5 = 0.40 mg/L. 0.132 is the LOD (3.3σ/S); 0.01 multiplies σ by S; 2.50 inverts.
Question 10 · medium
In India, laboratories testing food for regulatory purposes are commonly required to be accredited by
UKAS to ISO 9001
BIS to ISO 22000
FSSAI to Codex Type I methods
NABL to ISO/IEC 17025
Answer and working
D. NABL to ISO/IEC 17025
NABL is India's accreditation body for testing and calibration laboratories under ISO/IEC 17025.
A study plan for Food Analysis: Proximate, Chemical & Instrumental Methods in ICAR AICE-JRF/SRF
This plan follows where our questions actually fall, so the time goes where the marks are likely to be. It is our reading of the syllabus, not the exam body's weighting.
First, the heavy units (54% of the 69 questions): Method validation and quality control in the analytical laboratory (11, 16%); Mass spectrometry and hyphenated techniques (7, 10%); UV-visible, fluorescence and infrared spectroscopy (7, 10%); Chromatography: TLC, GC and HPLC (6, 9%); Electrophoresis and immunoassays: SDS-PAGE and ELISA (6, 9%).
Read the manual chapters for these first and do every worked question you can find on them.
Then the middle band: Vitamin analysis (6, 9%); Atomic absorption and ICP spectroscopy (5, 7%); Carbohydrates, sugars and dietary fibre (5, 7%); Moisture and total solids (3, 4%); Protein: Kjeldahl and Dumas methods (3, 4%).
Aim for one sitting per unit, then mixed questions across them.
Then the lighter units: Ash and mineral analysis (2, 3%); Fat: Soxhlet, Mojonnier and Gerber methods (2, 3%); Official methods and method compendia: AOAC, ISO and national manuals (2, 3%); Physical tests: pH, titratable acidity, refractometry and colour (2, 3%); Sampling and sample preparation (2, 3%).
Learn the definitions, classifications and standard numbers; these units are more often recalled than worked.
Leave time for the hard ones: Method validation and quality control in the analytical laboratory (5 hard of 11), Chromatography: TLC, GC and HPLC (2 hard of 6), Mass spectrometry and hyphenated techniques (2 hard of 7).
Come back to these after a first pass, untimed, and read every explanation, including for the options you rejected.
Bank the easy marks: Method validation and quality control in the analytical laboratory (2 easy of 11); Electrophoresis and immunoassays: SDS-PAGE and ELISA (1 easy of 6).
Do these early in revision so they are fast on the day.
Finish timed. Sit the subject as a timed set without notes, mark it, and send each wrong answer back to its unit above.