Original practice questions written to the published syllabus · not past papersRajasthan PSC — Assistant Agriculture Engineer (Agriculture Engineering syllabus) is a government recruitment exam run by Rajasthan Public Service Commission, for candidates in India. Objective paper; the paper structure was not captured.
Source: rpsc.rajasthan.gov.in.
Checked against the exam body's published information. Formats and fees change; confirm the current edition there before you book.
Rain to runoff: measuring precipitation, subtracting losses, estimating runoff and routing floods.
Our 37 Rajasthan PSC questions in this subject: 19 easy, 14 medium, 4 hard, across 12 units.
Choose an answer, then open the working. Each explanation says why the right answer is right and why the others are not.
These 10 were written to Rajasthan PSC and are not shown on any other exam's page.
Over one year a catchment receives 1,000 mm of rain, 350 mm leaves as runoff and evapotranspiration is 550 mm. Groundwater exchange across the divide is negligible. What is the change in catchment storage?
B. +100 mm (storage increases)
ΔS = P − R − ET = 1000 − 350 − 550 = +100 mm. A negative answer comes from reversing the sign convention; 1,900 mm adds all terms; 450 mm forgets the runoff term (1000 − 550).
A rain gauge is to be installed near a tree 8 m tall. Following the usual siting rule, the minimum distance from the tree is about:
D. 16 m
Obstructions should be no closer than about twice their height: 2 × 8 = 16 m. 8 m (equal to the height) is too close and the tree would shelter the gauge. 4 m is half the height, and 64 m squares the height instead of doubling it.
Double-mass analysis of rainfall records is used to:
C. check and correct the consistency of a station's record
A break in slope of the double-mass curve shows a change in gauge site, exposure or practice. Missing data are filled by the normal ratio or averaging methods, not by double-mass analysis.
The textbook pan coefficient commonly used to convert Class A pan evaporation to lake evaporation is about:
B. 0.7
About 0.7 (range roughly 0.6–0.8). A pan evaporates more than a lake, so the coefficient is less than 1; 1.3 would wrongly make the lake evaporate more. 0.3 is 1 − 0.7, the fraction by which the pan over-reads, not the coefficient.
A 1.2 km² reservoir has average Class A pan evaporation of 7.5 mm/day over a 30-day month. With a pan coefficient of 0.7, the evaporation loss is:
A. 189,000 m³
Lake evaporation = 0.7 × 7.5 × 30 = 157.5 mm; volume = 0.1575 × 1.2 × 10⁶ = 189,000 m³. 270,000 m³ forgets the pan coefficient; dividing by 0.7 applies it the wrong way; 1,890 m³ is a km²-to-ha slip. Dividing by 0.7 gives 270,000/0.7 = 385,714 m³.
At 8 a.m. on day 1 the water depth in an evaporation pan is 195 mm. At 8 a.m. on day 2 it is 188 mm, and 6 mm of rain fell in between. No water was added. The pan evaporation for the day is:
D. 13 mm
E = (195 − 188) + 6 = 13 mm, because the rain raised the level. 7 mm ignores the rain; 1 mm subtracts it; 9.1 mm wrongly applies a pan coefficient to the pan reading itself.
A grassed waterway drains 30 ha. The longest flow path is 700 m at a slope of 0.02, C = 0.45, and the local IDF relation is i = 1000 T^0.2/(D + 20)^0.8 (i in mm/h, D in min). For a 10-year return period, the design peak using Kirpich's tc is about:
D. 3.57 m³/s
tc = 0.01947 × 700^0.77 × 0.02^−0.385 = 13.6 min. i = 1000 × 10^0.2/(13.6 + 20)^0.8 = 95.2 mm/h. Q = 0.45 × 95.2 × 30/360 = 3.57 m³/s. Using a 60-minute duration instead of tc gives 1.78; entering tc in hours in the IDF formula gives 5.36 m³/s; the 3.6 constant with hectares gives 357 m³/s, 100 times too large.
A 60 ha catchment yields 35 mm of direct runoff in a storm. The runoff volume available for a farm pond is:
D. 21,000 m³
1 mm over 1 ha = 10 m³, so 35 × 10 × 60 = 21,000 m³. 2,100 and 210,000 m³ are factor-of-ten slips in the unit conversion, and 350 m³ forgets the area.
The reduction in the peak discharge of a flood as it passes through a reservoir or a reach is called:
D. attenuation
Attenuation is the lowering of the peak; translation is the delay in time. Both are caused by storage.
A district's seasonal rainfall departure from normal is −30%. In IMD's rainfall departure categories this is:
C. deficient
Normal is within ±19%, deficient −20 to −59% and large deficient −60 to −99%, so −30% is deficient.
This plan follows where our questions actually fall, so the time goes where the marks are likely to be. It is our reading of the syllabus, not the exam body's weighting.
Read the manual chapters for these first and do every worked question you can find on them.
Aim for one sitting per unit, then mixed questions across them.
Learn the definitions, classifications and standard numbers; these units are more often recalled than worked.
Come back to these after a first pass, untimed, and read every explanation, including for the options you rejected.
Do these early in revision so they are fast on the day.
Last updated · How Laisha writes and checks its pages · Report a mistake
US$10 a month · one price worldwide · cancel any time
| Free | Smarter | |
|---|---|---|
| Grow guides, pest pages, articles | Read all | Read all |
| Ask Laisha | 5 a day | Up to 1,000 a month |
| Exam practice | The sample on each page | Every question, timed papers |