Original practice questions written to the published syllabus · not past papersICAR AICE-JRF/SRF (PhD) — Agricultural Engineering subjects 38–43 is a PhD, fellowship and lectureship exam run by National Testing Agency for ICAR, for candidates in India. LAN-based computer test, 2 hours, 120 MCQs: 20 Part A (general knowledge and reasoning), 50 Part B (core group), 50 Part C (specialisation); four options.
Source: icar.org.in.
Checked against the exam body's published information. Formats and fees change; confirm the current edition there before you book.
Deeper conceptual questions: runoff generation mechanisms, IUH and Nash/Clark models, Muskingum parameter estimation and stability, frequency distributions, drought indices; hydrology of farm ponds and percolation ponds (subject 43).
Rain to runoff: measuring precipitation, subtracting losses, estimating runoff and routing floods.
Our 24 ICAR AICE-JRF/SRF questions in this subject: 1 easy, 6 medium, 17 hard, across 12 units.
Choose an answer, then open the working. Each explanation says why the right answer is right and why the others are not.
These 10 were written to ICAR AICE-JRF/SRF and are not shown on any other exam's page.
Three index stations at 4, 6 and 10 km from station X recorded 30, 40 and 22 mm. Using inverse-distance-squared weighting, estimate the rainfall at X.
D. 32.0 mm
Weights 1/16, 1/36, 1/100 = 0.0625, 0.0278, 0.0100. Px = (30×0.0625 + 40×0.0278 + 22×0.0100)/0.1003 = 32.0 mm. 31.7 mm uses 1/d, 30.7 mm is the simple mean, and weighting by d² gives most weight to the farthest station. Weighting by d² gives 27.1 mm.
An annual maximum daily rainfall series has mean 120 mm and standard deviation 40 mm. Using Gumbel's distribution with the infinite-sample frequency factor, the 100-year rainfall is about:
D. 245.5 mm
K = −(√6/π)[0.5772 + ln ln(100/99)] = 3.137; x = 120 + 3.137 × 40 = 245.5 mm. Using the reduced variate yT = 4.600 directly as K gives 304.0 mm; 223.7 mm is the 50-year value; 160 mm uses K = 1.
What is the probability that a 20-year event occurs exactly once in a 20-year period?
A. 0.377
Binomial: C(20,1) × 0.05 × 0.95¹⁹ = 0.377. 0.642 is the probability of at least one occurrence, which includes two or more. 1.000 is n × p (20 × 0.05), which is not a probability of exactly one event.
Using Meyer's formula E = C(ew − ea)(1 + u₉/16) with C = 0.36 for a large deep reservoir, estimate daily evaporation when ew = 23.76 mm Hg, ea = 11.88 mm Hg and u₉ = 16 km/h.
B. 8.55 mm/day
E = 0.36 × (23.76 − 11.88) × (1 + 16/16) = 0.36 × 11.88 × 2 = 8.55 mm/day. C = 0.50 is for small shallow waters; omitting the wind term gives 4.28; using ew instead of the difference gives 17.11.
In Nash's model of n equal linear reservoirs with storage constant k, the IUH u(t) = t^(n−1) e^(−t/k)/(kⁿ Γ(n)) peaks at t = (n − 1)k. For n = 3 and k = 2 h, the time to peak of the IUH and the basin lag (first moment) are:
A. 4 h and 6 h
Setting du/dt = 0 gives tpeak = (n − 1)k = 4 h; the first moment (lag) is nk = 6 h. 12 h is nk², the second moment about the centroid, not the lag.
Clark's instantaneous unit hydrograph is obtained by:
C. routing a time-area diagram of the catchment through a single linear reservoir
Clark combines translation (time-area histogram from isochrones) with storage (one linear reservoir). A cascade of n reservoirs is Nash's model.
At a gauging station on a flat river, measured discharges during a flood form a loop on the stage-discharge plot. At the same stage, discharge is:
C. greater on the rising limb, because the water-surface slope is steeper as the flood wave arrives
Unsteady flow gives a hysteresis loop: extra slope on the rising limb raises discharge for a given stage. The loop is physical, not error, and is corrected with slope or unsteady-flow methods.
Using Muskingum coefficients C₀ = 0.0323, C₁ = 0.6129 and C₂ = 0.3548, with inflow rising from I₁ = 40 to I₂ = 85 m³/s and outflow O₁ = 38 m³/s, the outflow at the end of the step is:
B. 40.7 m³/s
O₂ = C₀I₂ + C₁I₁ + C₂O₁ = 0.0323×85 + 0.6129×40 + 0.3548×38 = 40.7 m³/s. Swapping I₁ and I₂ gives 66.9; dropping the C₀I₂ term gives 38.0. 62.5 m³/s simply averages the two inflows.
For Muskingum routing with K = 10 h and x = 0.2, the range of routing interval Δt that keeps all three coefficients non-negative is:
B. 4 h ≤ Δt ≤ 16 h
C₀ ≥ 0 requires Δt ≥ 2Kx = 4 h; C₂ ≥ 0 requires Δt ≤ 2K(1 − x) = 16 h. The upper limit is not K itself, a common simplification.
Relative to the onset of meteorological drought, hydrological drought typically:
B. develops later and can persist after rainfall returns to normal
Streams, reservoirs and aquifers respond slowly, so hydrological drought lags and outlasts the rainfall deficit.
This plan follows where our questions actually fall, so the time goes where the marks are likely to be. It is our reading of the syllabus, not the exam body's weighting.
Read the manual chapters for these first and do every worked question you can find on them.
Aim for one sitting per unit, then mixed questions across them.
Learn the definitions, classifications and standard numbers; these units are more often recalled than worked.
Come back to these after a first pass, untimed, and read every explanation, including for the options you rejected.
Do these early in revision so they are fast on the day.
Last updated · How Laisha writes and checks its pages · Report a mistake
US$10 a month · one price worldwide · cancel any time
| Free | Smarter | |
|---|---|---|
| Grow guides, pest pages, articles | Read all | Read all |
| Ask Laisha | 5 a day | Up to 1,000 a month |
| Exam practice | The sample on each page | Every question, timed papers |
| Crop calendar and pest alerts | — | For your own fields |
| Calculators and tools | — | All |
| Uploads and reports | — | 100 a month, real files |
An AI operating system for agriculture: free guides, manuals and tools written for every country.