NCEES PE Agricultural and Biological Engineering · USA · NCEES (ASABE is the content partner)
Original practice questions written to the published syllabus · not past papersNCEES PE Agricultural and Biological Engineering is a licensing and registration exam run by NCEES (ASABE is the content partner), for candidates in USA. Computer-based, 85 questions, 9.5-hour appointment (8.5 hours of exam). Once a year (next: 28 Oct 2026). Closed book with the electronic NCEES handbook and supplied searchable ASABE standards; SI and US customary units.
Source: ncees.org.
Checked against the exam body's published information. Formats and fees change; confirm the current edition there before you book.
Facilities and Structures lists greenhouses: heat loss from U A ΔT plus infiltration, ventilation rate from a solar heat balance, fan and pad sizing, psychrometrics of evaporative cooling, and structural loads, in SI and US customary units.
Designing greenhouses and controlling the climate inside them, with the plastics and soilless systems that go with them.
Our 38 NCEES PE Agricultural and Biological Engineering questions in this subject: 1 easy, 22 medium, 15 hard, across 11 units.
Choose an answer, then open the working. Each explanation says why the right answer is right and why the others are not.
These 10 were written to NCEES PE Agricultural and Biological Engineering and are not shown on any other exam's page.
A free-standing single-span greenhouse is to be built at 45° N for winter vegetable production. Which ridge orientation gives the most winter light under the classic North American guidance?
D. Ridge running east–west, so the long south roof faces the low winter sun
Above about 40° latitude the low winter sun is best intercepted by a long south-facing roof, which an east–west ridge gives a free-standing house. North–south ridges are chosen for gutter-connected houses so that gutter shadows move; wind direction governs vent placement, not light.
Taking air density as 1.2 kg/m³, what is the wind velocity pressure q = 0.5ρV² for a design wind speed of 35 m/s on a greenhouse?
D. 735 Pa
q = 0.5 × 1.2 × 35² = 0.5 × 1.2 × 1,225 = 735 Pa. Leaving out the 0.5 gives 1,470 Pa; forgetting to square V gives 21 Pa; 368 Pa halves twice. The code then multiplies q by pressure coefficients for each face.
A greenhouse of 3,000 m³ leaks 1.5 air changes per hour. With ρcp = 1,200 J m⁻³ K⁻¹ and an inside–outside difference of 15 K, what is the sensible heat lost by leakage?
D. 22.5 kW
Q = ρcp N V ΔT / 3,600 = 1,200 × 1.5 × 3,000 × 15 / 3,600 = 22,500 W = 22.5 kW. 81.0 MW forgets to divide by 3,600 s per hour; 22.5 W comes from using ρcp = 1.2 (the kJ value) as if it were in J; 15.0 kW drops the 1.5 air changes to one.
Summer design: τ = 0.75, outside irradiance 900 W/m², floor area 2,000 m², fraction of absorbed energy used for evapotranspiration E = 0.4, cover area 3,000 m² with U = 5.5 W m⁻² K⁻¹, and the inside may run 5 K above outside. With ρcp = 1,200 J m⁻³ K⁻¹, what ventilation rate is needed?
B. 121 m³/s
Sensible gain = 0.75 × 900 × 2,000 × (1 − 0.4) = 810,000 W; cover loss = 5.5 × 3,000 × 5 = 82,500 W; Qv = (810,000 − 82,500) / (1,200 × 5) = 121 m³/s. Ignoring the cover loss gives 135; ignoring evapotranspiration gives 211; using 1,000 J m⁻³ K⁻¹ (cp without density) gives 146.
In still air, a greenhouse has 30 m² of effective opening split between side and roof vents whose centres are 4 m apart. Inside is 32 °C and outside 26 °C. Using Q = Cd A √[2gΔh(Ti − To)/Ti] with Cd = 0.65, what is the stack ventilation rate?
B. 24.2 m³/s
Ti must be absolute: 305.15 K. Q = 0.65 × 30 × √(2 × 9.81 × 4 × 6 / 305.15) = 0.65 × 30 × 1.242 = 24.2 m³/s. Using 32 °C in the denominator gives 74.8; leaving out Cd gives 37.3; dropping the 2 gives 17.1.
Why does a greenhouse with both low side vents and high roof vents ventilate better in calm weather than one with roof vents alone?
C. The height between inlet and outlet is larger, which strengthens the stack effect
Stack flow rises with the square root of Δh, the vertical distance between the centres of inlet and outlet, so low inlets and high outlets help when there is no wind. In calm weather there is no wind to exploit; vents are opened by motors, not wind; and vents do not double light.
Using the daytime balance and ignoring heat lost through the cover, what happens to the required ventilation rate if the allowed inlet-to-outlet temperature rise is reduced from 4 K to 2 K?
A. It doubles
Qv = sensible heat ÷ (ρcp ΔT), so with the heat load fixed the airflow is inversely proportional to ΔT; halving ΔT doubles it. This is why tight temperature limits make fan ventilation expensive and why evaporative cooling is added in hot weather.
Complete combustion of propane follows C₃H₈ + 5O₂ → 3CO₂ + 4H₂O. How much CO₂ does one kilogram of propane produce?
C. 3.0 kg
Molar mass of propane is 44 g/mol and each mole gives 3 mol CO₂ (3 × 44 = 132 g), so 132/44 = 3.0 kg CO₂ per kg. 2.75 kg is the methane figure (44/16); 1.0 kg counts one mole of CO₂ only; 4.0 kg uses the water moles.
What is the occupational exposure limit for CO₂, averaged over an eight-hour working day, used in many countries including the United States?
C. 5,000 ppm
The common 8-hour limit is 5,000 ppm (0.5%). Enrichment set points of roughly 700–1,000 ppm are far below it, but faulty dosing or a burst cylinder can exceed it, so alarms are fitted. 1,000 ppm is a typical enrichment set point, not a safety limit; 500 ppm is close to outdoor air. 50,000 ppm is a factor-of-ten slip (5%).
A recipe needs 250 mg/L potassium from potassium nitrate containing 38% K. The stock is dosed by a 1:200 injector. What concentration of potassium nitrate is needed in the stock tank?
A. 131.6 g/L
Salt in the final solution = 250 / 0.38 = 658 mg/L. The stock is 200 times stronger: 657.9 × 200 = 131,579 mg/L = 131.6 g/L. 65.8 g/L assumes a 1:100 ratio; 0.66 g/L is the final strength, not the stock; 50.0 g/L forgets that the salt is only 38% K.
This plan follows where our questions actually fall, so the time goes where the marks are likely to be. It is our reading of the syllabus, not the exam body's weighting.
Read the manual chapters for these first and do every worked question you can find on them.
Aim for one sitting per unit, then mixed questions across them.
Learn the definitions, classifications and standard numbers; these units are more often recalled than worked.
Come back to these after a first pass, untimed, and read every explanation, including for the options you rejected.
Do these early in revision so they are fast on the day.
Last updated · How Laisha writes and checks its pages · Report a mistake
US$10 a month · one price worldwide · cancel any time
| Free | Smarter | |
|---|---|---|
| Grow guides, pest pages, articles | Read all | Read all |
| Ask Laisha | 5 a day | Up to 1,000 a month |
| Exam practice | The sample on each page | Every question, timed papers |
| Crop calendar and pest alerts | — | For your own fields |
| Calculators and tools | — | All |
| Uploads and reports | — | 100 a month, real files |
An AI operating system for agriculture: free guides, manuals and tools written for every country.