Original practice questions written to the published syllabus · not past papersICAR AIEEA-PG — Agricultural Engineering & Technology (Major Subject Group 10) is a postgraduate admission exam run by National Testing Agency for ICAR, for candidates in India. Computer-based, 120 minutes, 120 MCQs, +4 / −1, English only (2026 bulletin). One paper for the whole subject group.
Source: icar.org.in.
Checked against the exam body's published information. Formats and fees change; confirm the current edition there before you book.
Basic instruments and measurement: errors, sensitivity, transducer classification, temperature and pressure measurement, ADC resolution and simple amplifier circuits.
Measuring temperature, pressure, flow, force and moisture, logging the data, and controlling processes automatically.
Our 40 ICAR AIEEA-PG questions in this subject: 36 easy, 4 medium, 0 hard, across 11 units.
Choose an answer, then open the working. Each explanation says why the right answer is right and why the others are not.
These 10 were written to ICAR AIEEA-PG and are not shown on any other exam's page.
A grain-store data logger reads 0.8 °C above a reference thermometer at every temperature tested. What kind of error is this, and how is it dealt with?
D. A systematic error, removed by applying a calibration correction of −0.8 °C
A constant offset that repeats under the same conditions is systematic. Averaging does not shrink it, because every reading carries the same bias; a calibration correction (the negative of the error) removes it. Hysteresis would show a difference between rising and falling inputs, not a constant offset.
A grain-probe temperature sensor has a time constant of 8 s. About how long after a step change does it show 95% of the change?
B. 24 s
A first-order response reaches 1 − e^(−3) = 95.0% at three time constants: 3 × 8 = 24 s. 8 s gives only 63.2%, 16 s (2τ) gives 86.5%, and 40 s (5τ) gives 99.3%.
A Pt100 sensor (α = 0.00385 /°C, linear model) in a pasteuriser hot-water line reads 119.4 Ω. What is the temperature?
C. 50.4 °C
R = R0(1 + αT), so T = (R/R0 − 1)/α = (1.194 − 1)/0.00385 = 50.4 °C. 310.1 °C forgets to subtract 1; 19.4 °C takes the ohms change as degrees; 7.5 °C multiplies the 19.4 Ω change by α (with a factor-of-100 slip) instead of dividing.
For a sharp-crested V-notch weir, discharge varies with upstream head H approximately as which power of H?
D. H^2.5
A triangular (V-notch) weir gives Q ∝ H^(5/2). H^1.5 is the rectangular weir; H^0.5 is the obstruction meter relation between flow and differential head.
A 120 Ω foil strain gauge with gauge factor 2.0 is bonded to a plough beam that is strained to 500 µε. What is the change in its resistance?
A. 0.12 Ω
ΔR = R·GF·ε = 120 × 2.0 × 500×10⁻⁶ = 0.12 Ω. 1.20 Ω uses 5000 µε; 0.06 Ω forgets the gauge factor. Changes this small are why a Wheatstone bridge is needed.
Strain gauges for measuring torque on a tractor PTO shaft are bonded at what angle to the shaft axis?
B. ±45°, along the principal strain directions of torsion
Pure torsion produces equal tensile and compressive principal strains at ±45° to the axis. Gauges along the axis or circumference see no strain from pure torsion.
Wheat has a moisture content of 15% wet basis. What is the moisture content on a dry basis?
D. 17.6%
Mdb = Mwb/(1 − Mwb) = 0.15/0.85 = 0.176 = 17.6%. 13.0% wrongly applies the reverse conversion (0.15/1.15); dry basis is always higher than wet basis for a moist product. 15.0% leaves the figure unconverted; 12.8% multiplies by (1 − Mwb) instead of dividing.
What is the size of one least significant bit (LSB) for a 12-bit ADC with a 0–5 V input range?
C. 1.22 mV
LSB = FS/2ⁿ = 5/4096 = 1.22 mV. 4.88 mV is the 10-bit value; 417 mV divides by the number of bits instead of 2ⁿ; 2.44 mV assumes a 10 V range.
A logger must resolve 0.1 °C over a 0–100 °C span. What is the minimum ADC resolution, assuming the full ADC range is used?
B. 10 bits
Steps needed = 100/0.1 = 1000; 2⁹ = 512 is too few and 2¹⁰ = 1024 is enough, so 10 bits. 8 bits gives only 256 steps (about 0.4 °C). In practice extra bits are chosen because noise and non-linearity reduce effective resolution. 7 bits gives 128 steps, enough only for about 0.8 °C; 12 bits works but is not the minimum.
Low-power wide-area network (LPWAN) radios are chosen for many farm sensors. What do they trade away to gain multi-kilometre range on battery power?
D. Data rate: they send only small packets, infrequently
LPWAN achieves long range at low power by using very low data rates and small payloads, often with duty-cycle limits. That suits a soil-moisture reading every 15 minutes, not video. Encryption is supported, and the radio does not change sensor accuracy.
This plan follows where our questions actually fall, so the time goes where the marks are likely to be. It is our reading of the syllabus, not the exam body's weighting.
Read the manual chapters for these first and do every worked question you can find on them.
Aim for one sitting per unit, then mixed questions across them.
Learn the definitions, classifications and standard numbers; these units are more often recalled than worked.
Do these early in revision so they are fast on the day.
Last updated · How Laisha writes and checks its pages · Report a mistake
US$10 a month · one price worldwide · cancel any time
| Free | Smarter | |
|---|---|---|
| Grow guides, pest pages, articles | Read all | Read all |
| Ask Laisha | 5 a day | Up to 1,000 a month |
| Exam practice | The sample on each page | Every question, timed papers |
| Crop calendar and pest alerts | — | For your own fields |
| Calculators and tools | — | All |
| Uploads and reports | — | 100 a month, real files |
An AI operating system for agriculture: free guides, manuals and tools written for every country.